Configure logging for troubleshooting
- Last UpdatedJul 09, 2025
- 2 minute read
- PI System
- Adapter for RDBMS 1.1
- Adapters
The AVEVA Adapter for RDBMS can be configured to perform data logging. Each message in the log displays the message severity level, timestamp, and the message itself.
For a list of severity levels and their descriptions, see Log levels.
Note: On successful execution, the log-level change takes effect immediately during runtime. The other configurations (log file size and file count) are updated after the adapter is restarted.
Postman
To configure logging using Postman:
-
To initialize the configuration, use the PUT method in conjunction with the following REST endpoints.
-
To update the log levels for the system logs, use the http://localhost:5590/api/v1/configuration/system/Logging REST endpoint.
-
To update the egress log level, use the http://localhost:5590/api/v1/configuration/omfegress/Logging REST endpoint.
-
To update specific adapter components, use the http://localhost:5590/api/v1/configuration/<componentId>/Logging REST endpoint.
Note: If you installed the adapter to listen on a non-default port, update 5590 to the port number in use.
-
-
Copy and paste an example configuration for logging into the Body section.
For sample JSONs, see the Examples section.
-
Update the example JSON parameters for your environment.
-
Select Send to push the configuration to the adapter.
EdgeCmd
To configure logging using EdgeCmd:
-
Using a text editor, create an empty text file.
-
Copy and paste an example configuration for logging into the file.
-
Update the example JSON parameters for your environment.
For sample JSONs, see the Examples section.
-
Save the file. For example, ConfigureLogging.json.
-
Open a command line session. Change directory to the location of your saved file.
-
Use one of the following edgecmd commands with the name of your JSON file.
edgecmd -port <port number> -cid <componentId> set Logging -file /.ConfigureComponentLogging.json
edgecmd -port <port number> -cid OmfEgress set Logging -file /.ConfigureEgressLogging.json
edgecmd -port <port number> -cid System set Logging -file /.ConfigureAdapterLogging.json