Typical High Availability and Disaster Recovery (HADR) planning might not account for system outages due to cyber attacks. Add cybersecurity planning either as a standalone plan or as part of HADR planning. A cybersecurity attack might not bring the entire system down, but might affect specific system components.
|
Step |
Action |
Notes Use this column to organize a deployment plan or to audit an existing plan. |
|
1 |
Protect the system from harm by considering mean time to failure for a defined list of system components. |
For example, include hot standby for real-time and application servers. |
|
2 |
Provide substitute system components along with a mechanism to exchange active and standby roles of the components. |
|
|
3 |
Take system components out of service by transferring component responsibilities to a substitute component no later than a defined percentage of mean time to failure. |
|
|
4 |
Initiate a transfer between active and standby system components manually at least once per a defined frequency. |
|
|
5 |
When a system component failure is detected, ensure that the standby system component successfully and transparently assumes its role within a defined time period and activates an alarm or automatically shuts down the system. |