Release notes
- Last UpdatedJan 07, 2025
- 3 minute read
- PI System
- PI Interface for OPC HDA 1.6.2
- Interfaces
PI Interface for OPC HDA
Version: 1.6.2.35
UniInt Version: 4.7.3.1
Overview
The PI Interface for OPC HDA is an OPC HDA client for bi-directional data transfer between an OPC HDA server and a PI System. The interface accesses data from the OPC HDA server.
This interface is available in two different options: read-only and read-write. The read-only option is strongly recommended for installation if updates to the data source are not needed. Since the read-only option cannot write to the data source, this option provides the best defense against accidental or malicious changes to the control system.
Version 1.6.2.35 is a general availability release that includes an upgrade to the UniInt Framework (v4.7.3). This version of the UniInt Framework includes security enhancements to the OMF Health Messaging system. See below f more information on product features and functions, including system requirements, and installation/uninstallation instructions.
Fixes and Enhancements
Fixes
There are no fixes in this release of PI Interface for OPC HDA.
Enhancements
The following enhancements are included in this release of PI Interface for OPC HDA:
|
Work Items |
Description |
|---|---|
|
111352 |
Upgraded to UniInt Framework 4.7.3 which simplifies OMF health configuration by reducing the number of fields required when configuring endpoints. |
Known Issues
There are no known issues related to this release of PI Interface for OPC HDA.
Security information and guidance
We are committed to releasing secure products. This section is intended to provide relevant security-related information to guide your installation or upgrade decision.
We proactively disclose aggregate information about the number and severity of security vulnerabilities addressed in each release. The tables below provide an overview of security issues addressed and their relative severity based on standard scoring.
Overview of New Vulnerabilities Found or Fixed
This section is intended to provide relevant security-related information to guide your installation or upgrade decision. We are proactively disclosing aggregate information about the number and severity of security vulnerabilities that are fixed in this release.
Security vulnerabilities fixed or mitigated
The following table lists the number of fixed vulnerabilities for PI Interface for OPC HDA by severity category and CVSS base score range.
|
Severity category |
CVSS base score range |
Number of vulnerabilities fixed |
|---|---|---|
|
Critical |
9.0 - 10 |
0 |
|
High |
7.0 - 8.9 |
0 |
|
Medium |
4.0 - 6.9 |
0 |
|
Low |
0 - 3.9 |
0 |
This table lists the known vulnerabilities along with their mitigation in this product.
|
Component |
Version |
CVE or Reference |
CVSS |
Mitigation |
|---|---|---|---|---|
|
SQLite |
3.43.0 |
BDSA-2023-3555 |
7.4 |
Vulnerable code is not in execution path. The session extension of SQLite is not utilized. |
|
SQLite |
3.43.0 |
BDSA-2023-3627 |
6.3 |
Vulnerable code is not in execution path. JSON parsing capability of SQLite is not utilized. |
Distribution Kit Files
|
Product |
Software Version |
|---|---|
|
Microsoft .NET Framework |
4.8 |
|
Microsoft Visual C++ 2015-2019 Redistributable (x64) |
14.21.27702 |
|
Microsoft Visual C++ 2015-2019 Redistributable (x86) |
14.21.27702 |
|
OSIsoft MS VB Runtime Redistributables |
1.0.1 |
|
PI Buffer Subsystem 2018 SP2 Patch 2 |
4.9.0.37 |
|
PI Generic Names DLL (PIGenericNames) |
1.3.5.25 |
|
PI Interface Configuration Utility (PI ICU) |
1.5.1.10 |
|
PI Interface for OPC HDA (OPCHDAInt) |
1.6.2.35 |
|
PI Interface for OPC HDA (OPCHDAInt) - ICU Control |
1.6.2.35 |
|
PI Interface for OPC HDA (OPCHDAInt) - Read-Only |
1.6.2.35 |
|
PI Network Subsystem Support (PINS) |
3.4.450.165 |
|
PI Software Development Kit (PI SDK) x64 2018 SP1 Patch 3 |
1.4.7.620 |
|
PI Software Development Kit (PI SDK) x86 2018 SP1 Patch 3 |
1.4.7.620 |
|
PI Spt DLL (PISpt) |
1.2.4.0 |