PI Interface for OPC HDA

Release notes

  • Last UpdatedJan 07, 2025
  • 3 minute read

PI Interface for OPC HDA

Version: 1.6.2.35
UniInt Version: 4.7.3.1

Overview

The PI Interface for OPC HDA is an OPC HDA client for bi-directional data transfer between an OPC HDA server and a PI System. The interface accesses data from the OPC HDA server.

This interface is available in two different options: read-only and read-write. The read-only option is strongly recommended for installation if updates to the data source are not needed. Since the read-only option cannot write to the data source, this option provides the best defense against accidental or malicious changes to the control system.

Version 1.6.2.35 is a general availability release that includes an upgrade to the UniInt Framework (v4.7.3). This version of the UniInt Framework includes security enhancements to the OMF Health Messaging system. See below f more information on product features and functions, including system requirements, and installation/uninstallation instructions.

Fixes and Enhancements

Fixes

There are no fixes in this release of PI Interface for OPC HDA.

Enhancements

The following enhancements are included in this release of PI Interface for OPC HDA:

Work Items

Description

111352

Upgraded to UniInt Framework 4.7.3 which simplifies OMF health configuration by reducing the number of fields required when configuring endpoints.

Known Issues

There are no known issues related to this release of PI Interface for OPC HDA.

Security information and guidance

We are committed to releasing secure products. This section is intended to provide relevant security-related information to guide your installation or upgrade decision.

We proactively disclose aggregate information about the number and severity of security vulnerabilities addressed in each release. The tables below provide an overview of security issues addressed and their relative severity based on standard scoring.

Overview of New Vulnerabilities Found or Fixed

This section is intended to provide relevant security-related information to guide your installation or upgrade decision. We are proactively disclosing aggregate information about the number and severity of security vulnerabilities that are fixed in this release.

Security vulnerabilities fixed or mitigated

The following table lists the number of fixed vulnerabilities for PI Interface for OPC HDA by severity category and CVSS base score range.

Severity category

CVSS base score range

Number of vulnerabilities fixed

Critical

9.0 - 10

0

High

7.0 - 8.9

0

Medium

4.0 - 6.9

0

Low

0 - 3.9

0

This table lists the known vulnerabilities along with their mitigation in this product.

Component

Version

CVE or Reference

CVSS

Mitigation

SQLite

3.43.0

BDSA-2023-3555

7.4

Vulnerable code is not in execution path. The session extension of SQLite is not utilized.

SQLite

3.43.0

BDSA-2023-3627

6.3

Vulnerable code is not in execution path. JSON parsing capability of SQLite is not utilized.

Distribution Kit Files

Product

Software Version

Microsoft .NET Framework

4.8

Microsoft Visual C++ 2015-2019 Redistributable (x64)

14.21.27702

Microsoft Visual C++ 2015-2019 Redistributable (x86)

14.21.27702

OSIsoft MS VB Runtime Redistributables

1.0.1

PI Buffer Subsystem 2018 SP2 Patch 2

4.9.0.37

PI Generic Names DLL (PIGenericNames)

1.3.5.25

PI Interface Configuration Utility (PI ICU)

1.5.1.10

PI Interface for OPC HDA (OPCHDAInt)

1.6.2.35

PI Interface for OPC HDA (OPCHDAInt) - ICU Control

1.6.2.35

PI Interface for OPC HDA (OPCHDAInt) - Read-Only

1.6.2.35

PI Network Subsystem Support (PINS)

3.4.450.165

PI Software Development Kit (PI SDK) x64 2018 SP1 Patch 3

1.4.7.620

PI Software Development Kit (PI SDK) x86 2018 SP1 Patch 3

1.4.7.620

PI Spt DLL (PISpt)

1.2.4.0

In This Topic