Recovery Mode
Enable/disable recovery mode.
Input Processing
|
Field |
Description |
|---|---|
|
Recovery Start Time |
Specifies the point in time at which recovery begins. Can be an absolute time, a relative time, or the name of a PI timestamp tag. (/Recovery_Time) Optional |
|
Recovery End Time |
Specifies the point in time at which recovery ends. Can be an absolute time, a relative time, or the name of a PI timestamp tag. (/Recovery_Time) Optional |
|
Input Recovery Step |
Specifies the size of chunk in which data is read during recovery, to avoid taxing system resources. Default is one day. Optional |
Output Processing
|
Field |
Description |
|---|---|
|
Recovery Start Time |
Specifies the point in time at which recovery begins. (/Recovery_Time) Optional |
|
Recovery End Time |
Specifies the point in time at which recovery ends. (/Recovery_Time) Optional |
|
Out of Order Options |
Specifies how out-of-order data is to be handled, for tags with Location5 set to 1. (/OOO_Options) Optional |