Supported features for PI Interface for Rockwell PharmaSuite Batch
- Last UpdatedNov 28, 2022
- 1 minute read
|
Feature |
Support |
|---|---|
|
Part number |
PI-IN-OS-RW-PS-NTI |
|
Auto-creates PI points and equipment assets? |
Yes |
|
Point Builder utility |
No |
|
Stores batch data in PIBatch Database and PI Module Database |
No |
|
Stores batch in PI AF |
Yes |
|
Supports equipment arbitration events |
No |
|
ICU (BIConfig.exe) |
No (use PI Event Frame Interface Manager configuration tool) |
|
PI point data types* |
Int32/ Float32/ String |
|
Sub-second timestamps |
Yes |
|
Sub-second scan classes |
No |
|
Automatically incorporates changes to PI point attributes |
No |
|
Exception reporting |
No |
|
Outputs from PI |
No |
|
Inputs to PI |
Event and scan-based |
|
Supports questionable bit |
No |
|
Supports multi-character PointSource |
Yes |
|
Maximum point count |
No maximum |
|
Uses PI SDK |
Yes: version 1.3.4.333 or higher required |
|
Uses AF SDK |
Yes: version 2.5.x or higher required |
|
PINet string support |
N/A |
|
Source of timestamps * |
BES (not system time on interface node) |
|
History recovery |
Yes |
|
UniInt-based |
No |
|
Disconnected startup * |
No |
|
SetDeviceStatus * |
Yes |
|
Failover |
No (not needed as the data source is historized) |
|
Vendor software required on PI interface node |
No |
|
Vendor hardware required |
No |
|
Additional PI software included with interface |
Yes |
|
Device point types |
The interface receives data from source as a JSON-formatted document and coerces the data into numerical types according to tag templates, if defined. |
|
Serial-based interface |
No |