Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI Interface for ABB 800xA Batch

Learn about event frames

  • Last UpdatedFeb 05, 2025
  • 5 minute read

Use event frames to record batch data. Event frames allow you to use recipe templates to define the attributes to be stored in event frames at every level of the hierarchy.

Each event frame contains the following fields:

  • Name

  • Description

  • Start time

  • End time

  • Template

  • Category (Default is "OSIBatch")

  • Batch properties (stored in event frame attributes)

  • Referenced elements such as unit or phase module

To view batch event frames and AF elements generated by the interface, use PI System Explorer. In the root-level event frame, the Name field contains the batch ID from the data source. In lower-level event frames, the Name field contains the recipe name. In event frames for a procedure-level recipe, the product and recipe properties from the data source are stored as attributes. For unit procedure-level recipes, the batch ID and product from the data source are stored as attributes.

If the highest recipe level is an operation or phase (that is, neither procedure nor unit procedure levels are defined), the interface creates event frames that correspond to the procedure and unit procedure level.

The following sections explain how data is stored in event frames for each level of the batch hierarchy.

Procedure

For each batch in the data source, the interface creates a root-level event frame that represents the procedure in the recipe. Each root-level event frame contains a collection of child event frames that correspond to unit procedures. Data from source batch events (that is, properties) can be recorded in the attributes of the event frame and in PI points. Source batches can have identical IDs and recipe names in the same time frame.

To match the source batch with an event frame, the interface stores additional information in the extended properties of the root event frame. The Name property contains the ID of the source batch, and the Value property contains an XML structure composed of the following batch data:

  • Batch ID

  • Product (searchable)

  • Formula name

  • Recipe (searchable)

  • Recipe type

  • Start time UTC

  • End time UTC

  • Interface name

  • Interface ID

  • Data source

    The following table shows how the source batch properties map to event frame data.

    Source Procedure Property

    Event Frame Field

    Event Frame Attribute

    BatchID

    Name

    Procedure Name

    Recipe

    Product

    Product

    Start Time

    Start Time

    End Time

    End Time

By default, the interface captures the following batch-associated properties and stores them in procedure-level event frame attributes:

  • Recipe header

  • Formula header

  • Recipe value

  • Report

For the preceding attributes, the name is assigned from the source [DESCRIPTION] column, the value from the source [PVALUE] columns, and the unit of measure attribute from the [EU] column.

The procedure-level event frame can represent merged source batches. The product and recipe attributes contain data associated with the source batch that started the merged event frame. For each merged source batch, the interface creates an entry node in the event frame's extended properties, named using the unique ID of the source batch, with its value containing an XML structure composed of the original source batch properties.

Unit Procedure

The interface creates a unit procedure-level event frame for each unit procedure read from the data source. Each unit procedure-level event frame is a child of the procedure-level event frame and contains the subset of event frames that represent the source batch operation-level recipe. The start and end times of an event frame record the start and end of physical processing in a unit.

The name field of the unit procedure-level event frames contains the unit procedure name as read from the data source. The batch ID and product properties are searchable attributes of the event frame. The following table shows how, by default, the source batch properties map to event frame data:

Source UnitProcedure Property

Event Frame Field

Event Frame Attribute

Reference Element

BatchID

BatchID

UnitProcedure Name

Name

Procedure

Product

Product

Start Time

Start Time

End Time

End Time

Unit

Unit

In addition to batch ID, procedure and product attributes, the interface records recipe and report events in event frame attributes. For these events, the attribute name is assigned from the [DESCRIPTION] column, the value from the source [PVALUE] column, and units of measure from the [EU] column.

Unit procedure-level event frame properties do not change if the parent object is a merged event frame. By default, unit procedure event frames contain the batch ID and procedure name read from the data source. (To override the default, use PI Event Frame Interface Manager to configure the Batch ID mask field on the Batch Settings page.)

When operation or phase-level recipes are run, the interface uses the operation or phase name as the name of the unit procedure-level event frame.

Operation

The interface creates an operation-level event frame for each operation read from the data source. Each operation-level event frame is a child of the unit procedure-level event frame and contains the subset of event frames that represent the source batch phase-level recipe.

The name field of the operation-level event frames is the operation name read from the data source. The following table shows how the source batch properties map to event frame attributes:

Source Operation Property

Event Frame Field

Reference Element

Operation Name

Name

Start Time

Start Time

End Time

End Time

Unit

Unit

By default, the interface records recipe value and report events in event frame attributes. For these events, the attribute name is assigned from the [DESCRIPTION] column, the value from the source [PVALUE] column, and units of measure from the [EU] column.

Phase

The interface creates a phase-level event frame for each phase read from the data source. Each phase-level event frame is created as a child of an operation-level event frame and contains the subset of event frames that represent the source batch phase states-level recipe.

The name field of the phase-level event frame contains the phase name read from the data source. The following table shows how the source batch properties map to event frame attributes:

Source Phase Property

Event Frame Field

Reference Elements

Phase Name

Name

Start Time

Start Time

End Time

End Time

Unit

Unit

Phase Module

Phase Module

By default, the interface records recipe value and report events in event frame attributes. For these events, the attribute name is assigned from the [DESCRIPTION] column, the value from the source [PVALUE] column, and units of measure from the [EU] column.

Phase State

The interface creates a phase state-level event frame for each phase state read from the data source. Each phase state-level event frame is created as a child of a phase-level event frame and, if so configured, can contain the subset of event frames that represent the phase steps. The start of new phase state ends the previous one, unless the new state is COMPLETE, ABORTED or STOPPED, which end the current phase state without beginning a new one. These phase states have a zero-duration time frame.

The name field of the phase state event frames reflects an actual source recipe phase state name. Below is the mapping of source phase state to event frame fields and attributes:

Source Phase State Property

Event Frame Field

Referenced Element

Phase State

Name

Start Time

Start Time

End Time

End Time

Unit

Unit

Operation Module

Operation Module

Phase Module

Phase Module

Phase Step