Learn about batch setup tab
- Last UpdatedFeb 05, 2025
- 1 minute read
Use the settings on this tab to identify the elements for various batch settings.
Report as step
Select this option and then set a Start and an End date.
Alternate PI module path
Select this option to specify an alternate PI Module path or PI AF element path for a particular equipment hierarchy. Select Find module to open the Browse to PI Module Path window to navigate to the desired PI module. Select the PI Module to display the path in the Module path field, then select OK.
Disable arbitration
Select this option to create unit batches based solely on source batch recipe data. Select this option when the source Batch Executive System (BES) provides batch data without equipment arbitration data.
Disable arbitration counters
Select this option to direct the interface to release a unit on the first resource release event even if the number of acquire events is higher than the number of release events.
True batch start date
Select this option to use top level recipe start/end events for creating batch objects.
Allow deferred units
Select this option to enable the creation of unit batches for recipes in units that are allocated at the phase level rather than the unit batch level.