Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI Interface for AVEVA Batch Management

PI Interface for AVEVA Batch Management 5​.1​.13 release notes

PI Interface for AVEVA Batch Management 5​.1​.13 release notes

  • Last UpdatedSep 17, 2026
  • 3 minute read

PI Interface for AVEVA Batch Management (formerly PI Interface for WonderWare InBatch) collects data from an AVEVA Batch Management Batch Execution System. The interface supports AVEVA Batch Management versions 8.1 SP1 and above. This interface creates Event Frames in PI AF based on data from AVEVA Batch Management. PI Tags and an AF Hierarchy are automatically created to capture additional context around your process data

PI Interface for AVEVA Batch Management 5.1.13, released September 2026, is a maintenance release addressing minor bug fixes.

For more information on product features and functions, including system requirements and installation/uninstallation instructions, refer to PI Interface for AVEVA Batch Management guide.

The latest information about the 5.1.13 release is available online on the AVEVA Documentation Portal.

New features and enhancements

There are no new features or enhancements in this release.

Resolved issues

This section lists items resolved in this release:

Work Item

Description

94985

PI user can now contain '\' escape sequence.

97876

The Batch will no longer wait to update batch events until the batch closes.

101917

The data source queries now support multibyte character set

108380

UNIT is no longer defaulted to create a unit element in the root elements collection of PI System Explorer.

113307

During recovery, unclosed batches will be included

115323

Using custom names for the "UnitProcedure" recipe name will no longer cause incorrect end times for children Event Frames.

116606

Batch Interfaces gracefully exit on shutdown

117835

Phase States now have the correct end time when all phase states are processed in a single scan

118769

PI Event Frames Interface Manager ENABLEDMONITORTAGS page now persists the selections made between opening and closing as long as all changes are saved.

120215

EngUnits are no longer capitalized during property event creation.

120272

The [TIMESTAMP] placeholder uses a period to designate subseconds rather than a colon.

122305

Elements no longer have case sensitivity that could impact child event frames with element names that different by case.

131715

Child phases no longer start after the parent operation has closed.

Known Issues

There are no known issues for this release.

Security information and guidance

We are committed to releasing secure products. This section is intended to provide relevant security-related information to guide your installation or upgrade decision.

We proactively disclose aggregate information about the number and severity of security vulnerabilities addressed in each release. The tables below provide an overview of security issues addressed and their relative severity based on standard scoring.

Overview of new vulnerabilities - Fixed or Mitigated

This section is intended to provide relevant security-related information to guide your installation or upgrade decision. AVEVA is proactively disclosing aggregate information about the number and severity of PI Interface for AVEVA Batch Management security vulnerabilities that are fixed in this release.

For this release of PI Interface for AVEVA Batch Management, the following vulnerabilities have been fixed or mitigated.

Security vulnerabilities fixed in PI Interface for AVEVA Batch Management 5.1.13 release

Severity Category

CVSS Base Score Range

Number of Fixed Vulnerabilities

Critical

9 - 10

0

High

7.0 - 8.9

0

Medium

4.0 - 6.9

0

Low

0 - 3.9

0

Vulnerability mitigations in PI Interface for AVEVA Batch Management 5.1.13 release

Component

Version

CVE or Reference

CVSS

Mitigation

SQLite

3.43.0

BDSA-2023-3555

7.4

Vulnerable code is not in execution path. The session extension of SQLite is not compiled into the code base.

SQLite

3.43.0

BDSA-2025-3096

7.1

We make no call to sqlite3_db_config.

SQLite

3.43.0

BDSA-2025-7046

6.5

Vulnerable code is not in execution path.

SQLite

3.43.0

BDSA-2023-3627

6.3

Vulnerable code is not in execution path. JSON parsing capability of SQLite is not utilized.

Distribution Kit Files

Product

Software Version

Microsoft Visual C++ 2015-2019 Redistributable (x86)

14.21.27702.2

Microsoft Visual C++ 2015-2019 Redistributable (x64)

14.21.27702.2

PI Network Subsystem

3.5.510.290

PI AF Client 2018 SP3 Patch 5

2.10.11.2717

Microsoft OLE DB Driver 19 for SQL Server

19.2.0.0

PI Interface for AVEVA Batch Management (AVEVABatchManagement)

5.1.13.10