Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI Interface for Emerson DeltaV Batch

Windows Credential Manager for authentication

  • Last UpdatedJul 29, 2025
  • 2 minute read

As a security best practice, PI Interface for Emerson DeltaV Batch stores any credentials that you enter during interface configuration to Windows Credential Manager. PI Interface for Emerson DeltaV Batch uses these credentials to authenticate with:

  • PI Data server

  • PI Asset Framework

  • The batch interface data source

Storage of credentials within Windows Credential Manager benefits you by:

  • Caching credentials for future authentication, so that you do not have to re-enter them.

  • Removing any reference to passwords within the interface instance .ini file.

  • Encrypting the credentials.

    Tip: For more information on where to configure credentials that PI Interface for Emerson DeltaV Batch uses for authentication, see:

Credential creation

When you configure an interface using the PI Event Frames Interface Manager, PI Interface for Emerson DeltaV temporarily writes the credentials that you enter to the applicable .ini file. These settings remain in the .ini file until you start the interface.

After you start PI Interface for Emerson DeltaV Batch, it makes the following updates:

  • All credentials are saved to Windows Credential Manager.

  • Within the interface .ini file, any reference to passwords are removed.

Credential storage

After you start PI Interface for Emerson DeltaV Batch, the credentials that it uses for authentication with PI components and data sources are listed in Windows Credential Manager.

The following table lists credentials for PI Interface for Emerson DeltaV Batch:

Credentials

Name

PI Data server

EMDVB_X_PI

PI Asset Framework

EMDVB_X_AF

Batch interface data source

EMDVB_X_Source_Y

Note: X is a placeholder for an interface instance Service ID. Y is a placeholder for a data source instance number.

To update credentials

If you need to update the credentials that the interface uses for authentication, edit the configuration settings for the instance using PI Event Frames Interface Manager.

  1. From Interface Selection, select the applicable PI Interface for Emerson DeltaV Batch instance.

  2. From Server Information, update the credentials used to authenticate with PI Data server or PI Asset Framework.

  3. From Source, update the credentials used to authenticate with a data source.

  4. Select Save Settings.

    Result: The credentials are updated within the instance configuration. Restart the interface to update the credentials within Windows Credentials Manager.