PI Interface for Ramp Soak Simulator Data

Startup command file

  • Last UpdatedNov 23, 2022
  • 2 minute read

The Ramp Soak interface default point source is 9.

For Windows, command file names have a .bat extension. The Windows continuation character (^) allows for the use of multiple lines for the startup command. The maximum length of each line is 1024 characters (1 kilobyte). The number of parameters is unlimited, and the maximum length of each parameter is 1024 characters.

PI-ICU provides a tool for configuring the interface startup command file.

The Ramp Soak interface on Windows has an ICU Control that will aid in configuring the Ramp Soak interface startup command file:

The Ramp Soak control for PI-ICU has two sections. A yellow text box indicates that an invalid value has been entered, or that a required value has not been entered.

General

When the Fill time gaps with data box is checked, the interface will, at startup, generate and backfill data for the time since the last shutdown. This is useful for demonstration systems that are stopped and started often (on a laptop, for example). A gap time can also be specified, which will cause the interface to generate data only as far back as is specified-for example, "2h" will cause the interface to generate a maximum of 2 hours' worth of data from the time it is started. The default time increment is seconds. If 's', 'm', 'h', or 'd' is not specified, then the time defaults to 's'. The command line equivalent is /nogap=x, where x is the maximum number of seconds of data to backfill.

Additional arguments

The Additional Arguments section is provided for any flags that may have been required in the future.