Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI Powershell

ResetPITuningParameter Class

  • Last UpdatedDec 15, 2025
  • 3 minute read
ResetPITuningParameter Class

Reset a PI Data Archive tuning parameter on a PI Data Archive

The Reset-PITuningParameter cmdlet resets a PI Data Archive Tuning Parameter back to its default value by clearing the current value.

The connection parameter specifies which connection to a PI Data Archive to use.

Inheritance Hierarchy

SystemObject
  InternalCommand
    Cmdlet
      PSCmdlet
        OSIsoft.PowerShellOSICmdletBase
          OSIsoft.PowerShellOSICmdletBaseWithConnection
            OSIsoft.PowerShellResetPITuningParameter

Namespace:  OSIsoft.PowerShell
Assembly:  OSIsoft.PowerShell (in OSIsoft.PowerShell.dll) Version: 3.1.1.0 (3.1.1.466)

Syntax

[CmdletAttribute("Reset", "PITuningParameter", SupportsShouldProcess = true)]
public class ResetPITuningParameter : OSICmdletBaseWithConnection
<CmdletAttribute("Reset", "PITuningParameter", SupportsShouldProcess := true)>
Public Class ResetPITuningParameter
	Inherits OSICmdletBaseWithConnection

Dim instance As ResetPITuningParameter
[CmdletAttribute(L"Reset", L"PITuningParameter", SupportsShouldProcess = true)]
public ref class ResetPITuningParameter : public OSICmdletBaseWithConnection
[<CmdletAttribute("Reset", "PITuningParameter", SupportsShouldProcess = true)>]
type ResetPITuningParameter =  
    class
        inherit OSICmdletBaseWithConnection
    end

The ResetPITuningParameter type exposes the following members.

Constructors

  NameDescription
Public method
ResetPITuningParameter

Properties

  NameDescription
Public property
Connection

Connection to a PI Data Archive from which to reset the tuning parameter

(Overrides OSICmdletBaseWithConnectionConnection.)
Public property
Name

Name of the PI Data Archive tuning parameter to reset to the default value

Examples

Reset-PITuningParameter Archive_LowDiskSpaceMB -Connection $con

Where:

$con = Connect-PIDataArchive -PIDataArchiveMachineName "PISRV1"

Resets the Archive_LowDiskSpaceMB tuning parameter from the "PISRV1" PI Data Archive server. The default value for Archive_LowDiskSpaceMB can be examined using "Get-PITuningParameter -Name Archive_LowDiskSpaceMB -Connection $con".

See Also

TitleResults for “How to create a CRG?”Also Available in