Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Edge Data Store

Schedules

  • Last UpdatedSep 25, 2025
  • 2 minute read

You can configure the adapter to run scans based on a schedule. Each data item can be assigned to a schedule in the data selection configuration. The adapter samples data for those data items at the scheduled time.

Note: You start an ingress component without a schedule configuration. A default schedule configuration is added to use as an example.

Note: When the adapter framework scheduler misses or skips a scan for any reason, either one of the following messages is printed: Scan skipped for schedule id <Id> or Scan missed for schedule <id>.

Configure schedules

Complete the following steps to change the schedules configuration:

  1. Using any text editor, create a file that contains the schedules configuration in the JSON format.

  2. Save the file. For example, ConfigureSchedules.json.

  3. Use any of the tools capable of making HTTP requests to run a PUT command with the contents of the file to the following endpoint: http://localhost:5590/api/v1/configuration/<ComponentId>/Schedules.

    Note: Replace <ComponentId> with the ComponentId of the adapter.

    5590 is the default port number. If you selected a different port number, replace it with that value.

    Example using curl or EdgeCmd:

    Note: Run this curl command or EdgeCmd from the same directory where the file is located.

    curl -d "@Modbus1ConfigureSchedules.json" -H "Content-Type: application/json" -X PUT "http://localhost:5590/api/v1/configuration/<ComponentId>/Schedules"

    edgecmd set schedules -cid Modbus1 -file Modbus1ConfigureSchedules.json

    On successful execution, the schedules change takes effect immediately during runtime.

Schedules parameters

The following parameters are available for configuring schedules:

Parameter

Required

Type

Description

Id

Required

string

Unique identifier for the schedule.

Allowed value: any string identifier

Period

Required

string

The data sampling rate of the schedule. The expected format is HH:MM:SS.###.

Invalid inputs: null, negative timespan, or zero

A default value must be specified.

Offset

Optional

string

The offset from the midnight when the schedule starts. The expected format is HH:MM:SS.###

Invalid input: negative timespan

A default value must be specified.

Note: You can also specify timespans as numbers in seconds. For example, "Period": 25 specifies 25 seconds, or "Period": 125 specifies 2 minutes and 5 seconds.

Example schedule configuration

The following is an example of a complete schedule configuration:

[

{

"Id": "schedule1",

"Period": "00:00:01.500",

"Offset": "00:02:03"

}

]

Default schedule configuration

If no schedule is configured, the adapter uses the following default schedule configuration:

[

{

"Id": "1",

"Period": "0:00:05",

"Offset": "0:00:00"

}

]

REST URLs

Relative URL

HTTP verb

Action

api/v1/configuration/ComponentId/Schedules

GET

Gets all configured schedules

api/v1/configuration/ComponentId/Schedules

DELETE

Deletes all configured schedules

api/v1/configuration/ComponentId/Schedules

POST

Adds an array of schedules or a single schedule. Fails if any schedule already exists

api/v1/configuration/ComponentId/Schedules

PUT

Replaces all schedules

api/v1/configuration/ComponentId/Schedules/id

GET

Gets configured schedule by Id

api/v1/configuration/ComponentId/Schedules/id

DELETE

Deletes configured schedule by Id

api/v1/configuration/ComponentId/Schedules/id

PUT

Replaces schedule by Id. Fails if schedule does not exist

api/v1/configuration/ComponentId/Schedules/id

PATCH

Allows partial updating of configured schedule by Id

Note: Replace ComponentId with the Id of your adapter component.

In This Topic