Defect ID

Description

Workaround

3932870

During the upgrade of Operations Control Logger on a node running SP2023, the Install Toolkit displays a service stop window where the name of the process and 'in use by application' details are missing.

N/A

3895279

SP2020R2SP1P01 is not compatible with Operations Control Logger 23.4.

Versions below SP2023 are not compatible with Operations Control Logger 23.4.

3886299

After upgrading to Logger version OCL 23.4 on a system with Batch Management 2023, Aveva Configurator cannot configure Batch Management Events.

Batch Management 2023 and Batch Management 2023 R2 versions are not compatible with Operations Control Logger 23.4.

3849005

After upgrading or installing Logger version Operations Control Logger 23.4 build 20250318.4 (from Operations Control Logger 22.1) on a System Platform All-in-One machine, the IDE crashes during Galaxy deployment.

Affected Version:

  • System Platform 2023

For SP2023:

  1. Run lusrmgr.msc.

  2. Add the current domain user to the ASBSolution and AsbCoreServices groups.

  3. Restart the machine.

  4. Back up zlib1.dll from: C:\Program Files (x86)\Common Files\ArchestrA\.

  5. Upgrade Logger to version 23.4 on the machine.

  6. Replace the zlib1.dll from backup to C:\Program Files (x86)\Common Files\ArchestrA\.

  7. Replace wnwrapServerEx.exe in C:\Program Files (x86)\Common Files\ArchestrA\.

    Note: If unable to replace directly, rename existing binaries and then copy the same. The binaries will be provided by the respective product teams.

  8. Replace ptacc.dll in C:\Program Files (x86)\Wonderware\InTouch\.

  9. Reboot the machine.

  10. Validate Logger and IDE functionality (Create Galaxy / Deploy).

    For SP2023 R2:

  11. Back up zlib1.dll from: C:\Program Files (x86)\Common Files\ArchestrA\.

  12. Upgrade Logger to version 23.4 on the machine.

  13. Replace the zlib1.dll from backup to C:\Program Files (x86)\Common Files\ArchestrA\.

  14. Replace wnwrapServerEx.exe in C:\Program Files (x86)\Common Files\ArchestrA\.

    Note: If unable to replace directly, rename existing binaries and then copy the same. The binaries will be provided by the respective product teams.

  15. Replace ptacc.dll in C:\Program Files (x86)\Wonderware\InTouch\.

  16. Reboot the machine.

  17. Validate Logger and IDE functionality (Create Galaxy / Deploy).

    For SP2023R2SP1P01

  18. Upgrade Logger to version 23.4 on the machine.

  19. Replace ptacc.dll in C:\Program Files (x86)\Wonderware\InTouch\.

  20. Reboot the machine.

  21. Validate Logger and IDE functionality (Create Galaxy / Deploy).