Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI Connector for IEC 61850

Release notes

  • Last UpdatedNov 03, 2023
  • 2 minute read

PI Connector for IEC 61850

2.0.0.27

Overview

PI Connector for IEC 61850 collects electrical substation asset information and real time data from IEC 61850 servers to store it in the PI System.

Fixes and Enhancements

Fixes

There are no fixes with this release.

Enhancements

This section lists enhancements that were added in this release:

Enhancements

Description

158415

Added support for IEDs which use ACSE security.

205177

Added support for DC Functional Constraints.

228616

Data collection performance has been improved.

249075

PI Connector for IEC 61850 is now on new distributed architecture.

271659

Added support for the Point Source field on PI Points.

Known Issues

There are no known issues with this release.

System Requirements

Operating Systems

This connector is a 64-bit application which runs on 64-bit architecture systems.

Server Class

Client Class

2008 R2 SP1 or later

7 SP1, 8.1, 10 or later

Distribution Kit Files

Product

Software Version

Microsoft .NET Framework 4.7 Setup

4.7.02053.00

Microsoft Visual C++ 2019 Redistributable(x64)

14.21.27702.0

PI Connector for IEC 61850

2.0.0.27

Installation and Upgrade

Installing PI Connector for IEC 61850

The PI Connector for IEC 61850 can be installed or upgraded using the installation kit. This installation kit can be obtained by using the How to Download Products link listed in the OSIsoft Customer Portal How To's list. This list is located on the OSIsoft Customer Portal site.

For additional information regarding the PI Connector for IEC 61850 installation, please see the Prepare for connector installation and Install the connector sections of the user guide. The user guide is located in the PI Connectors section of the Doc Library.

Uninstalling PI Connector for IEC 61850

The PI Connector for IEC 61850 can be uninstalled using the Programs and Features list accessible from the Windows Control Panel. After accessing the Programs and Features list, select the PI Connector for IEC 61850 and then select Uninstall to uninstall the interface.

Security information and guidance

We are committed to releasing secure products. This section is intended to provide relevant security-related information to guide your installation or upgrade decision.

We proactively disclose aggregate information about the number and severity of security vulnerabilities addressed in each release. The tables below provide an overview of security issues addressed and their relative severity based on standard scoring.

No additional security vulnerabilities are applicable to this release.

Overview of New Vulnerabilities Found or Fixed

This release of PI Connector for IEC 61850 contains three (3) reported security issues.

This table lists the known vulnerabilities along with their mitigation in this product.

Component

Version

CVE or Reference

CVSS

Mitigation

angular/core

4.4.4

CVE-2021-4231

5.4

This vulnerability does not apply to PI Connectors because they do not implement Server-Side Rendering (SSR).

ag-grid

12.0.1

CVE-2017-16009

6.1

This vulnerability does not apply to PI Connectors because they do not use Angular expressions and AngularJS.

Bouncy Castle

1.8.1

CVE-2020-15522

5.9

This vulnerability does not apply to PI Connectors because they do not use ECDSA Encryption.