Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI Interface for Emerson DeltaV Batch

Release notes

  • Last UpdatedAug 21, 2025
  • 3 minute read

PI Interface for Emerson DeltaV

Version 5.1.12.41

Overview

PI Interface for Emerson DeltaV captures batch, manufacturing, and process data from an Emerson DeltaV System. The interface collects data from a DeltaV SQL server or EVT files, converts this data to PI tags and PI batch properties, and stores the collected data as event frames and elements within the PI Asset Framework (PI AF). You can use tag templates to control PI point creation and event population.

Fixes and Enhancements

Enhancements

There are no enhancements for this release.

Fixes

This section lists items that were resolved or added in this release of PI Interface for Emerson DeltaV.

Work Item

Description

116606

Batch Interfaces gracefully exit on shutdown.

117835

Phase States now have the correct end time when all phase states are processed in a single scan.

118769

The ENABLEDMONITORTAGS command line parameter now persists the selections made between opening and closing as long as all changes are saved.

120215

EngUnits are no longer capitalized during property event creation.

120272

The [TIMESTAMP] placeholder uses a period to designate subseconds instead of a colon.

121711

All phase states are properly closed after changes or updates on the data source.

122305

Elements no longer have case sensitivity to impact child event frames with element names that are different by case.

Known Issues

There are no known issues for this release.

Security information and guidance

We are committed to releasing secure products. This section is intended to provide relevant security-related information to guide your installation or upgrade decision.

We proactively disclose aggregate information about the number and severity of security vulnerabilities addressed in each release. The tables below provide an overview of security issues addressed and their relative severity based on standard scoring.

Overview of new vulnerabilities - Fixed or Mitigated

This section is intended to provide relevant security-related information to guide your installation or upgrade decision. AVEVA is proactively disclosing aggregate information about the number and severity of PI Interface for Emerson DeltaV security vulnerabilities that are fixed in this release.

For this release of PI Interface for Emerson DeltaV, the following vulnerabilities have been fixed or mitigated.

Security vulnerabilities fixed in PI Interface for Emerson DeltaV 5.1.12.41 release

Severity Category

CVSS Base Score Range

Number of Fixed Vulnerabilities

Critical

9 - 10

0

High

7.0 - 8.9

0

Medium

4.0 - 6.9

0

Low

0 - 3.9

0

Vulnerability mitigations in PI Interface for Emerson DeltaV 5.1.12.41 release

Component

Version

CVE or Reference

CVSS

Mitigation

SQLite

3.43.0

BDSA-2023-3555

7.4

Vulnerable code is not in the execution path. The session extension of SQLite is not compiled into the code base.

SQLite

3.43.0

BDSA-2025-3096

7.1

We make no call to sqlite3_db_config.

SQLite

3.43.0

BDSA-2025-7046

6.5

Vulnerable code is not in execution path.

SQLite

3.43.0

BDSA-2023-3627

6.3

Vulnerable code is not in the execution path. JSON parsing capability of SQLite is not utilized.

Distribution Kit Files

Product

Software Version

Microsoft Visual C++ 2015-2019 Redistributable (x86)

14.21.27702.2

Microsoft Visual C++ 2015-2019 Redistributable (x64)

14.21.27702.2

PI Network Subsystem

3.4.450.165

PI AF Client 2018 SP3 Patch 4

2.10.10.2539

Microsoft OLE DB Driver 19 for SQL Server

19.2.0.0

PI Interface for Emerson DeltaV Batch (EMDVB)

5.1.12.41

*The PI Network Subsystem Support (PINS) component is not displayed on the installation welcome screen if Data Archive is installed already.

In This Topic