PI Interface for Siemens SIMATIC Batch

Property templates

  • Last UpdatedFeb 05, 2025
  • 2 minute read

Property templates enable you to configure how data from the data source is written to event frame attributes or batch database properties. Each interface provides a set of default properties, which contain commonly-desired data. To add these properties, right-click the Property Templates node and choose Add Default Templates.

Configuration

  • Index

    Assigns a unique numeric identifier for the template.

  • Name

    Specifies how the property is named. You can use placeholders to include values emitted by the data source. By default, properties reside under a parent recipe property. To specify a location in the hierarchy where you want the property to reside, define the name as a path, delimited using backslashes. For example, to specify that all properties generated using this template are located under a parent property named "Materials" plus the contents of the Event field, specify the name as follows: Materials\[Event]. To create the property at the root level, precede the name with a dollar sign: $\[Event].

  • Value

    Specifies the value to be recorded. Use placeholders to include values from the data emitted by the data source.

  • Create property

    Specifies the level at which the property is to be created. Options are as follows:

    • At recipe level: By default, properties are created at the recipe level corresponding to the level in the data source from which the data was read.

    • Under root node: Create properties at the top level of the batch or event frame hierarchy, regardless of the level at which they originated.

    • Under UniqueID node: (Batch database only, not event frames) Create properties under the batch's UniqueID node.

  • Data type

    PI data type of the value. Note that if the incoming value is incompatible with the specified type, the event is not processed, and an error is logged.

  • Translate

    Maps text from the data source to the text that you want to record in the PI System.

  • UOM

    Unit of measure to be used to store value, if different from unit provided by data source.

Advanced features

  • Descriptor

    Populates the tag's Descriptor field.

  • Engineering units

    Unit of measurement.

  • Category

    Specifies the PI AF category to be associated with the value.