List of Data Archive tuning parameter settings (Topology 4)

List of Data Archive tuning parameter settings (Topology 4)

  • Last UpdatedMar 23, 2026
  • 1 minute read

The table below lists the tuning parameter settings for Data Archive.

Data Archive tuning parameter

Parameter value

Archive Subsystem, Piarchss_ThreadCount 

  • Topology 4A: 2

  • Topology 4B: 6

Archive SubSystem, Archive_AutoArchiveFileSize 

  • Topology 4A: 2

  • Topology 4B: 6

Snapshot SubSystem, PIsnapss_ThreadCount

  • Topology 4A: 2

  • Topology 4B: 6

Update Manager SubSystem, MaxUpdateQueue

100,000,000

Update Manager SubSystem, TotalUpdateQueue

1,000,000,000

Update Manager SubSystem, PIupdmgr_ThreadCount

  • Topology 4A: 2

  • Topology 4B: 6

How do I change Data Archive tuning parameter settings?

Data Archive Tuning parameters are changed in PI System Management Tools (PI SMT). See Edit Data Archive tuning parameters.