Analytics and Notifications for PI System Explorer (PI Server 2024 R2)

Steam_HPTL

  • Last UpdatedJan 11, 2023
  • 1 minute read

Calculate the liquid specific enthalpy as a function of pressure (P in kPa) and temperature (T in °C). Only use for compressed water. For any T greater than the saturation temperature for P, the function returns an out-of-range error. The function accepts any T in the temperature range as long as P is greater than the critical pressure. By default, input arguments and returned values are in SI units. You can change the units of measure, for example, by using the Convert function.

Syntax

Steam_HPTL(P, T)

Arguments

  • P

    Pressure of the steam. P can range from 0.611212678 to 100000 kPa.

  • T

    Temperature of the steam. T can range from 0.0 to 800 °C.

Returns

Computed liquid specific enthalpy in J/g.

Example

  • Steam_HPTL(40000, 100)

    [Returns 449.27 J/g]