List of Data Archive tuning parameters (Topology 3)

List of Data Archive tuning parameters (Topology 3)

  • Last UpdatedNov 13, 2025
  • 1 minute read

The table below lists the tuning parameter settings for Data Archive.

Data Archive tuning parameter  

Parameter value 

Archive Subsystem, Piarchss_ThreadCount 

Topology 3A: 6

Topology 3B: 16

Topology 3C: 20

Archive SubSystem, Archive_AutoArchiveFileSize 

Topology 3A: 1,024

Topology 3B: 2,048

Topology 3C: 4,096

Snapshot SubSystem, PIsnapss_ThreadCount 

Topology 3A: 6

Topology 3B: 16

Topology 3C: 20

Update Manager SubSystem, MaxUpdateQueue 

100,000,000

Update Manager SubSystem, TotalUpdateQueue  

1,000,000,000

Update Manager SubSystem, PIupdmgr_ThreadCount 

Topology 3A: 6

Topology 3B: 16

Topology 3C: 20

How do I change Data Archive tuning parameter settings?

Data Archive Tuning parameters are changed in PI System Management Tools (PI SMT). See Edit Data Archive tuning parameters.