Enable auto-dynamic archive conversion
- Last UpdatedOct 04, 2024
- 1 minute read
- PI System
- PI Server 2018
- PI Server
Automatic conversion of full fixed archives to dynamic archives is enabled by default for PI Server 3.4.375 and later. However, if you upgrade from an earlier version of PI Server, this parameter may not be enabled.
Beginning with PI Server PR1 SP1a (3.4.375.59), auto-dynamic archives preserve their shift flag and turn into fixed size archives again if they become primary archives.
Use this procedure to enable the automatic conversion of full fixed archives to dynamic archives, for versions prior to 3.4.375:
-
Select Start > PI System Management Tools > Operation > Tuning Parameters and click the Archive tab.
-
Select the Archive_Enable_AutoDynamic parameter and set the Value to 1.
Data Archive Version
Auto-dynamic Archive Conversion Behavior
Prior to 3.4.375
If you upgrade from a version of PI Server prior to 3.4.375 to a version prior to 2012, the Archive_Enable_AutoDynamic parameter might not be enabled.
PI Server PR1 SP1a (3.4.375.59)
Beginning with PI Server PR1 SP1a (3.4.375.59), auto-dynamic archives preserve their shift flag and turn into fixed size archives again if they become primary archives. The Archive_Enable_AutoDynamic tuning parameter is enabled by default.
PI Server 2012
The Archive_Enable_AutoDynamic tuning parameter is deprecated. Automatic conversion of full fixed archives to dynamic archives is default behavior.