Besides on-demand history recovery, the adapter also supports automatic history recovery.

For automatic history recovery, the adapter tracks changes to the DeviceStatus of each component.

  • When the DeviceStatus changes to DeviceInError or Shutdown, the adapter starts a new history recovery interval.

  • When the issue resolves or if the adapter is restarted and the DeviceStatus changes to Good, the adapter closes any current intervals for that component.

The adapter tracks these intervals for each component and, when DeviceStatus has a value of Good, it performs history recovery for these intervals starting from oldest to newest. See Device status for more information.

Note: If the data collection mode is set to CurrentWithBackfill, the adapter clears periods not recovered for the component and stops keeping track of them. Only if the data collection mode is set to HistoryOnly, an automatic history recovery operation in progress will be canceled, otherwise it will be finished.

History recovery intervals

Automatic history intervals cannot be longer than four days. If an interval is longer than four days, the adapter automatically changes the start time of the interval to be no earlier than four days before the end time prior to starting a recovery. If a current outage lasts longer than four days, when the device status finally improves the adapter recovers up to four days before the current time. This avoids introducing additional data gaps.