The following EdgeCmd commands configure specific facets of the data endpoints:

EdgeCmd command

Description

Examples

edgecmd get DataEndpoints [-file <filepath>]

Get the data endpoints configuration.

edgecmd get DataEndpoints

edgecmd set DataEndpoints [-file <filepath>]

Import the data endpoints configuration.

edgecmd set DataEndpoints -file C:\Users\TestUser\DataEndpoints\Configuration.json

edgecmd add DataEndpoints [-id <endpointId>] [-Endpoint <endpointUrl>] [-UserName <userName>] [-Password <password>] [-ClientId <clientId>] [-ClientSecret <clientSecret>] [-TokenEndpoint <tokenEndpoint>] [-ValidateEndpointCertificate <true/false>]

Add data endpoints.

edgecmd add DataEndpoints -id PI Web Api -Endpoint https://pi_web_api_server/piwebapi/omf/ -UserName TestUser -Password TestPassword -ValidateEndpointCertificate false

edgecmd edit DataEndpoints -id <string> [-Endpoint <endpointUrl>] [-UserName <userName>] [-Password <password>] [-ClientId <clientId>] [-ClientSecret <clientSecret>] [-TokenEndpoint <tokenEndpoint>] [-ValidateEndpointCertificate <true/false>]

Change a data endpoint.

edgecmd edit DataEndpoints -id PI Web Api -Endpoint https://pi_web_api_server/piwebapi/omf/ -UserName TestUser -Password TestPassword -ValidateEndpointCertificate true

edgecmd remove DataEndpoints -id <string> [-y]

Remove the specified data endpoint.

edgecmd remove DataEndpoints -id PI Web API

edgecmd remove DataEndpoints [-y]

Remove all data endpoints.

edgecmd remove DataEndpoints -y

edgecmd help DataEndpoints

Display help output for the data endpoints configuration.

Use EdgeCmd utility to add and remove adapter, and to configure facets of the components.

Note: The examples in this topic are using the default port number 5590. If you specified a different port number for your adapter, you need to add it in the command. For example: edgecmd -port 5591 <RestOfTheCommand>

If a command contains slashes, you must add escape characters as follows:

In Windows , add a second slash. style="box-sizing: inherit;">
Example: TestUser\OilCompany becomes TestUser\\OilCompany

In Linux , add three additional slashes. style="box-sizing: inherit;">
Example: TestUser\OilCompany becomes TestUser\\\\OilCompany