Enumeration sets for cnc_statinfo function parameters
- Last UpdatedFeb 23, 2023
- 4 minute read
The tables in this topic list all of the enumeration sets defined by the PI Connector for FANUC Focas for the cnc_statinfo function parameters. The connector-defined enumeration sets directly reflect the status defined in the FANUC Focas library documentation for cnc_statinfo.
Note: In some cases the name in the connector-generated enumeration set differs from the name in the FANUC Focas library documentation due to constraints in PI AF.
alarm
The following tables define the status of the alarm parameter:
-
Enumeration set name: Alarm_16_Above (CNC and M/T Types: Any type supported by the connector except for 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
OTHERS
***(Others)
0
ALARM
ALarM
1
BATTERY_LOW
BATtery low
2
FAN
FAN(NC or Servo amplifier)
3
PS_WARNING
PS Warning
4
FSSB_WARNING
FSsB warning
5
INSULATE_WARNING
INSulate warning
6
ENCODER_WARNING
ENCoder warning
7
PMC_ALARM
PMC alarm
8
NOT_DEFINED
9
-
Enumeration set name: Alarm_16iW_18iW (CNC and M/T Types: 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NO_ALARM
****(Not emergency)
0
ALARM
ALARM
1
BATTERY_LOW
BATTERY LOW
2
NOT_DEFINED
3
aut
The following tables define the status of AUTOMATIC mode selection.
-
Enumeration set name: Aut_16_Above (CNC and M/T Types: Any type supported by the connector except for 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
MDI
MDI
0
MEMORY
MEMory
1
NA
****
2
EDIT
EDIT
3
HANDLE
HaNDle
4
JOG
JOG
5
TEACH_IN_JOG
Teach in JOG
6
TEACH_IN_HANDLE
Teach in HaNDle
7
INC_FEED
INC-feed
8
REFERENCE
REFerence
9
REMOTE
ReMoTe
10
NOT_DEFINED
11
-
Enumeration set name: Aut_16i-W_18i-W (CNC and M/T Types: 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
MDI
MDI
0
MEM
MEM
1
EDT
EDT
3
HAND
HAND
4
JOG
JOG
5
TAPE
TAPE
10
NOT_DEFINED
11
edit
The following tables define the status of program editing.
-
Enumeration set name: Edit_16_Above_M (CNC and M/T Types: CNC types above 16; M series)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NOT_EDITING
****(Not editing)
0
EDIT
EDIT
1
SEARCH
SeaRCH
2
OUTPUT
OUTPUT
3
INPUT
INPUT
4
COMPARE
COMPARE
5
LABEL_SKIP
Label SKip
6
RESTART
ReSTaRt
7
HPCC
HPCC
8
PTRR
PTRR
9
RVRS
RVRS
10
RTRY
RTRY
11
RVED
RVED
12
HANDLE
HANDLE
13
OFFSET
OFfSeT
14
WORK_OFFSET
Work OFfSet
15
AICC_AI_APC
AICC AI APC
16
MEMORY_CHECK
MEmory-CHecK
17
CUSTOMERS_BOARD
CusToMer´s BoarD
18
SAVE
SAVE
19
AI_NANO
AI NANO
20
AI_APC
AI APC
21
MBL_APC
MBL APC
22
NANO_HP_AICC2_AICC
NANO HP AICC 2 AICC
23
AI_HPCC
AI HPCC
24
_5_AXIS
5-AXIS
25
LEN
LEN
26
RAD
RAD
27
WZR
WZR
28
TCP
TCP
39
TWP
TWP
40
TCP_AND_TWP
TCP+TWP
41
APC
APC
42
PRG_CHK
PRG-CHK
43
APC_0i_D
APC
44
S_TCP
S-TCP
45
AICC_2
AICC 2
46
ALLSAVE
ALLSAVE
59
NOTSAVE
NOTSAVE
60
NOT_DEFINED
61
-
Enumeration set name: Edit_16_Above_T (CNC and M/T Types: CNC types above 16; T series)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NOT_EDITING
****(Not editing)
0
EDIT
EDIT
1
SEARCH
SeaRCH
2
OUTPUT
OUTPUT
3
INPUT
INPUT
4
COMPARE
COMPARE
5
LABEL_SKIP
Label SKip
6
OFFSET
OFfSeT
7
WORK_SHIFT
Work ShiFT
8
RESTART
ReSTaRt
9
RVRS
RVRS
10
RTRY
RTRY
11
RVED
RVED
12
PTRR
PTRR
14
AICC_AI_APC
AICC AI APC
16
MEMORY_CHECK
MEmory-CHecK
17
SAVE
SAVE
19
AI_NANO
AI NANO
20
HPCC
HPCC
21
NANO_HP_AICC2_AICC
NANO HP AICC 2 AICC
23
AI_HPCC
AI HPCC
24
_5_AXIS
5-AXIS
25
OFSX
OFSX
26
OFSZ
OFSZ
27
WZR
WZR
28
OSFY
OFSY
29
TOFS
TOFS
31
TCP
TCP
39
TWP
TWP
40
TCP_AND_TWP
TCP+TWP
41
APC
APC
42
PRG_CHK
PRG-CHK
43
APC_0i_D
APC
44
S_TCP
S-TCP
45
ALLSAVE
ALLSAVE
59
NOTSAVE
NOTSAVE
60
NOT_DEFINED
61
-
Enumeration set name: Edit_16i-W_18i-W (CNC and M/T Types: 16i-W and 18i-W )
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NOT_EDITING
****(Not editing)
0
EDITING
EDITING
1
SEARCH
SEARCH
2
RESTART
RESTART
3
RETRACE
RETRACE
4
NOT_DEFINED
5
emergency
The following tables define the status of emergency.
-
Enumeration set name: Emergency_16_Above (CNC and M/T Types: Any type supported by the connector except for 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NOT_EMERGENCY
(Not emergency)
0
EMERGENCY
EMerGency
1
RESET
ReSET
2
WAIT
WAIT
3
NOT_DEFINED
4
-
Enumeration set name: Emergency_16i-W_18i-W (CNC and M/T Types: 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NOT_DEFINED
0
motion
The following tables define the status of axis movement.
-
Enumeration set name: Motion_16_Above (CNC and M/T Types: Any type supported by the connector except for 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NA
***
0
MOTION
MoTioN
1
DWELL
DWeLl
2
NOT_DEFINED
3
-
Enumeration set name: Motion_16i-W_18i-W (CNC and M/T Types: 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NA
****
0
CMTN
CMTN
1
CDWL
CDWL
2
NOT_DEFINED
3
mtsb
The following tables define the status of M, S, T, B function.
-
Enumeration set name: MTSB_16_Above (CNC and M/T Types: Any type supported by the connector except for 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
OTHERS
***(Others)
0
FIN
FIN
1
NOT_DEFINED
2
-
Enumeration set name: MTSB_16i-W_18i-W (CNC and M/T Types: 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NA
****
0
CFIN
CFIN
1
NOT_DEFINED
2
run
The following tables define the status of automatic operation.
-
Enumeration set name: Run_16_Above (CNC and M/T Types: Any type supported by the connector except for 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
RESET
****(reset)
0
STOP
STOP
1
HOLD
HOLD
2
START
STaRT
3
MSTR
MSTR
4
NOT_DEFINED
5
-
Enumeration set name: Run_16i-W_18i-W (CNC and M/T Types: 16i-W and 18i-W)
Name in connector-defined enumeration set
Status in FANUC Focas Documentation
Integer Value
NOT_READY
NOT READY
0
M_READY
M-READY
1
C_START
C-START
2
F_HOLD
F-HOLD
3
B_STOP
B-STOP
4
NOT_DEFINED
5