Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

Asset Framework and PI System Explorer (PI Server 2024 R2)

Renumber enumeration values

  • Last UpdatedJan 11, 2023
  • 2 minute read

You can renumber an enumeration set although you will invalidate objects where the value is currently being used.

  1. Right-click anywhere in a field and select Renumber Enumeration Values.

    The Change Enumeration Value confirmation window explains that you will invalidate objects already using the existing enumeration set.

  2. To continue, click Yes.

  3. In the Starting Values field of the Renumber window, click to increase or lower the value.

  4. In the Increment by field, click to select an increment value.

    If you select a row before renumbering, renumbering starts at the selected row, with this row getting the starting value and each subsequent row getting the next value of increment. Only the selected row and following rows are changed during a renumber action. If renumbering does not start at the topmost row, a possibility of the generated values being identical to the values above the selected row exists. The following error message is displayed:

    Attempting to change the enumeration values would overlap previous enumeration values prior to the selected row.

Related Links
TitleResults for “How to create a CRG?”Also Available in