Enable PI Data Archive access for the PI identity
- Last UpdatedJan 03, 2025
- 1 minute read
- PI System
- PI Connector for UFL 1.3.2.139
- Connectors
Provide the new PI identity for the connector with the required access to the Data Archive using PI System Management Tools.
Note: You must have already created a PI identity for the connector.
-
Launch PI System Management Tools, and then select Security > Database Security.
-
Right-click the PIPOINT table and then select Properties.
The Security window opens.
-
Select Add to open the Select window, and then select the identity to add to the access control list.
-
Enable read and write access to the PIPOINT table, and then select OK to save the settings and close the window.