Configure batch events
- Last UpdatedJan 14, 2025
- 2 minute read
- PI System
- PI Event Frames Generator 5.1.7
- Interfaces
To generate hierarchical batch events using PI EFGen and the PI Event Frames Configuration Utility, configure three levels: Procedure, Unit Procedure, and Operation, as shown in the following figure:
Configuring procedure-level batch events
Configure the settings for this event type as follows:
|
Field |
Setting |
|---|---|
|
Configuration Name |
RE100 Batch Procedure |
|
Event Frame Template |
EFSimProcedure |
|
Active Point Name |
RE100.Active |
|
Active Point Behavior |
Pulse |
|
Event Frame Name |
Choose Use this PIPoint value and enter TIME.YEARMONTHDAYTIME |
In the Attribute Names table, configure the following attributes:
|
Attribute Name |
Configuration |
Value |
|---|---|---|
|
Product |
PIPoint |
RE100.Product |
|
Recipe |
PIPoint |
RE100.Recipe |
Select the Other Settings tab. Omit the Primary Reference Element. In the Default Settings section, configure the following settings:
-
Recovery Time: 1 day
-
Evaluation Delay: 10 seconds.
To save the configuration, select Save Settings.
Configuring unit procedure-level batch events
Configure the settings for this event type as follows:
|
Field |
Setting |
|---|---|
|
Configuration Name |
RE100 Unit Procedure (add as child of RE100 Batch Procedure) |
|
Event Frame Template |
EFSimUnitProcedure |
|
Active Point Name |
RE100.Active |
|
Active Point Behavior |
Pulse |
|
Event Frame Name |
Choose Use this PIPoint value and enter TIME.YEARMONTHDAYTIME |
In the Attribute Names table, configure the following attributes:
|
Attribute Name |
Configuration |
Value |
|---|---|---|
|
BatchID |
PIPoint |
TIME.YEARMONTHDAYTIME |
|
Procedure |
PIPoint |
RE100.Procedure |
|
Product |
PIPoint |
RE100.Product |
Select the Other Settings tab and add RE100 as the primary reference element. In the Default Settings section, check Enable and configure an evaluation delay of 10 seconds. To save the configuration, select Save Settings.
Configuring operation-level batch events
Configure the settings for this event type as follows:
|
Field |
Setting |
|---|---|
|
Configuration Name |
RE100 Operation (add as child of RE100 Unit Procedure) |
|
Event Frame Template |
EFSimOperation |
|
Active Point Name |
RE100.Phase |
|
Active Point Behavior |
Step |
|
Event Frame Name |
Choose ActivePoint value |
No attribute configuration is required.
Select the Other Settings tab. Omit the primary reference element. In the Default Settings section, check Enable and configure an evaluation delay of 10 seconds. To save the configuration, select Save Settings.