Install PI EFGen
- Last UpdatedJan 14, 2025
- 1 minute read
- PI System
- PI Event Frames Generator 5.1.7
- Interfaces
This checklist summarizes the steps for installing this interface. If you are familiar with running PI data collection interface programs, this checklist helps you get the interface running.
-
Confirm that you can use PI SMT to configure the PI Server. You need not run PI SMT on the same computer on which you install the interface.
-
If you are running the interface on computer other than the server node, create a PI trust that permits the interface to write data.
-
Download and run the PI EFGen interface installation kit.
-
If you are running the interface on an interface node, verify that the system time and time zone are set correctly.
-
Run the PI Event Frames Interface Manager and configure a new instance of this interface. Essential startup parameters for this interface are as follows:
-
Point source (/PS=x)
-
Interface ID (/ID=#)
-
PI Server (/Host=<node name>:<port>)
-
PI AF server (/AFHost=<AF node name>) and database (/AFDatabase=<databasename>)
-
Event frame definitions
-
-
Start the interface interactively in statistics mode by specifying the command line parameter /mode=stat. Confirm that the interface can connect to the PI Server and data sources and collect data successfully.
-
Configure the interface to run as a Window service and confirm that it runs properly.
-