Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ PI Server 2024 R2

AVEVA PI Server 2024 R2 - Release Notes

  • Last UpdatedDec 08, 2025
  • 7 minute read

Overview

AVEVA™ PI Server 2024 R2 is a feature release that focuses on performance, accessibility, and manageability. This release also includes a variety of bug fixes and security remediations to improve the stability and functionality of Data Archive and PI Asset Framework (AF).

The AVEVA PI Server 2024 R2 installation kit has updated components for Data Archive, AF Server, PI Notifications Service, PI AF Client, and PowerShell Tools for the PI System. Some of the other components including Buffer Subsystem, PI Analysis Service, PI SMT, PI SDK, and PI Collective Manager remain at the same version as delivered in the previous release.

For more information on system requirements and installation, see the following topics:

New features and enhancements

The following new features are introduced in AVEVA PI Server 2024 R2:

  • Enhanced cloud-managed support for PI AF: You can now store PI Asset Framework (AF) data in Microsoft Azure SQL Managed Instance and Amazon RDS for SQL Server, expanding deployment options for cloud-hosted environments. See Learn about a PI AF server installation and upgrade.

  • Redundant single sign-on (SSO) support: PI Data Archive, PI Asset Framework, PI Analysis Service, PI Notification Service, and PI PowerShell now support redundant SSO (RSSO) configurations by leveraging enhanced redundancy capabilities in AVEVA Identity Manager (AIM), improving availability for claims-based authentication via OpenID Connect (OIDC). See Configure AVEVA Identity Manager for redundancy.

  • Audit Trail support for cloud-hosted environments: Audit Trail functionality in PI AF is now available in the three supported cloud database platforms, which include Microsoft Azure SQL Database, Microsoft Azure SQL Managed Instance, and Amazon RDS for SQL Server. Audit Trail enables organizations to track and review changes to PI AF objects, as well as key system and security settings, ensuring robust traceability and compliance across hybrid and cloud deployments. See Track PI AF changes with Audit Trail.

Resolved issues

This table lists the issues addressed in this release.

Product / Component

WI / PLI

Description

Asset Framework

78363

Resolved: PI AF elements (AFElements) are no longer loaded as duplicates in multithreaded environments such as PI Analytics.

Asset Framework

99307

Resolved: Searches in PI AF now complete without error, even when the user lacks read access to the target database.

Asset Framework

107481

Resolved: Implemented retry logic in AF SDK for the RecordedValuesAtTimes method to address handle error "[-11148] Maximum number of concurrent bulk queries limit exceeded".

Asset Framework

108987

Resolved: SQL Server no longer creates system change data capture (CDC) tables in the wrong file group when used with PI Asset Framework. CDC tables are now correctly placed, improving database organization and performance.

Asset Framework

112170

Resolved: The unexpected Server Error: 'SQL Error (102) Incorrect syntax near ')'.'. no longer occurs in search requests when the user does not have permissions on all objects returned in the search results.

Asset Framework

118547

Resolved: PI AF no longer locks the system when claims authentication is used by default and a check security call is issued after an access token expired.

Asset Framework

120526

Resolved: Lock contention issues no longer occur in multithreaded applications with large number of requests that use CheckSecurity on one thread while running refresh on separate threads.

Asset Framework

120873

Resolved: After renaming a PI Collective, AF SDK clients no longer return the following error message when trying to connect to a PI collective: The given key '<OldCollectiveName>' and service name '<NewCollectiveName>' do not match. This issue has been fixed.

Asset Framework

121826

Resolved: Loading user permissions when an AF SQL database contained many AF identities has been corrected. Users no longer receive the "Access Denied: The user <DOMAIN\account> does not have rights to read the PI AF Server" error when attempting a connection.

Asset Framework

122398

Resolved: The AVEVA PI OIDC Configuration tool now correctly configures the thumbprint for Data Archive.

Asset Framework

124210

Resolved: AF SDK application no longer holds onto a stale access token if a connection to PI Data Archive is lost shortly after refreshing the token.

Asset Framework

123499

Resolved: OIDC 'Role' Mappings could not be recreated through PI Builder because of incorrectly loaded MappingAccountName. This issue has been fixed and roles created using PI SMT can now be imported and exported correctly from PI Builder.

Asset Framework

123611

Resolved: The AF SDK application fails to edit OIDC mappings and returns the following error: [-10352] IdentityMapping type cannot be edited. This issue has been fixed and OIDC mappings can now be edited using the AF SDK.

PI Notifications Service

110908

Resolved: Replaced CefSharp with WebView2 to improve security and allow customers to install and manage Chromium dependencies separate from the PI Notifications Service installation.

PI Notifications Service

111184

Resolved: The Notifications Management tab now correctly uses OIDC authentication when available, eliminating unnecessary prompts for Windows credentials.

PI Notifications Service

122386

Resolved: Compatibility has been restored between PI System Explorer 2024 and PI Notifications Service 3.0.x (2023/2023 Patch 1). Connecting no longer triggers a “Could not load file or assembly” exception.

PI Notifications Service

123251

Resolved: The repair and change operations for PI Notifications Service 2024 via Windows Control Panel now complete successfully without installation failure.

Data Archive

70636

Resolved: Steam table methods now use the IAPWS R7-97 (2012) library, which is based on the Industrial Formulation 1997 for water and steam. The updated implementation is concurrency-safe, more accurate, and supports a broader range (1073 K to 2273 K, 0–50 MPa).

See Steam functions (tag-based calculations).

Data Archive

106405

Resolved: Fixed an issue where collective replication in Data Archive failed with error “[-10566] Point validation failed” if the access control list (ACL) included a deleted identity during point creation. This error no longer occurs, and replication now completes successfully even when ACLs contain previously deleted identities.

Data Archive

121557

Resolved: Setting Archive_MaxQueryExecutionSec to 0 previously caused timeouts during multipoint, single-timestamp data retrieval calls. This configuration now works as expected without triggering timeouts.

Data Archive

116557

Resolved: The piartool -thread "subsystem" -info command has been updated to return only valid thread information for tasks that are actively executed. This ensures that customers receive accurate and relevant diagnostics without misleading or incomplete data.

Data Archive

119426

Resolved: Previously, PI Update Manager could fail when attempting to load a corrupted events queue file for a persistent consumer. PI Update Manager now handles corrupted queue files reliably, maintaining system stability and continuity.

Data Archive

8543

Resolved: The PIUPD_MaxConsTimeout configuration setting is now correctly applied, ensuring that data consumers remain connected and are no longer disconnected every two minutes.

Data Archive

76996

Resolved: Archive shifting now correctly accommodates the creation of new PI Points beyond the initial primary region size. This prevents the error [-11053] No more available records in this archive and ensures sufficient archive space is maintained.

Data Archive

111523

Resolved: OIDC authentication no longer fails during PI Network Manager startup when the AIM service is inactive. The system now handles this scenario gracefully.

Data Archive

111821

Resolved: The archive subsystem now correctly handles high-volume tag operations. It no longer writes data to incorrect tags when many tag deletions, creations, and event writes occur in rapid succession.

Data Archive

111944

Resolved: Data points that reference previously deleted tags are now reliably flushed by the archive subsystem. This ensures consistent data handling and prevents potential data loss.

Data Archive

115542

Resolved: Two new tuning parameters have been added to address timeout issues:

  • AIMRoleRetrievalTimeout: Extends the RPC timeout beyond the default 30 seconds to support longer-running operations.

  • MaxHTTPBasicParserPayloadBody: Increases the allowable page data size beyond the previous 8 MB limit, improving performance for large payloads.

Known issues

There are no known issues or upgrade compatibility considerations in AVEVA PI Server 2024 R2. Refer to the AVEVA Support portal page for a complete list of known issues in previous versions.

Security information and guidance

We are committed to releasing secure products. This section is intended to provide relevant security-related information to guide your installation or upgrade decision.

We proactively disclose aggregate information about the number and severity of security vulnerabilities addressed in each release. The tables below provide an overview of security issues addressed and their relative severity based on standard scoring.

Vulnerabilities fixed

This table lists the number of fixed vulnerabilities in this release by severity category and CVSS base score range. Both vulnerabilities were found and fixed in PI Data Archive.

Severity category

CVSS base score range

Number of fixed vulnerabilities

Critical

9.0 - 10

0

High

7.0 - 8.9

1

Medium

4.0 - 6.9

0

Low

0 - 3.9

0

Vulnerabilities mitigated

The following table provides details on the specific vulnerabilities mitigated in this release, along with the corresponding component, version, CVE or reference, CVSS score, and the mitigation applied.

Component

Version

CVE or Reference

CVSS

Mitigation

SQLite

3.50.2

BDSA-2025-11433

7.3

Vulnerable code is not in the execution path.The FTS5 extension is not included as part of the build set.

Distribution kits

This table lists the exact versions included in the 2024 R2 distribution kits. Use these numbers to confirm what was installed, plan safe upgrades, and share precise component versions during troubleshooting.

Product

Software version

Microsoft Visual C++ 2022 Redistributables (x86 and x64)

14.42.34438

Microsoft VSTO 2010 Runtime

10.0.60917

OSIsoft MS VB Runtime Redistributables

1.0.2

PI Buffer Subsystem

4.9.0.37

PI Network Subsystem

3.5.510.290

PowerShell Tools for the PI System

3.1.1.466

PI AF Client 2024 R2

3.1.1.1182

PI AF Server 2024 R2

3.1.1.1182

PI Analysis Service

3.1.0.1156

PI Notifications Service

3.1.1.1033

PI Data Archive 2024 R2

3.5.510.359

PI Software Development Kit (PI SDK)

1.4.7.620

PI System Management Tools 2023

3.7.0.272

PI Collective Manager 2018 SP3 Patch 1

1.4.3.25

Aveva.PI OIDC Configuration Tool

1.0.3.97

©2025 AVEVA Group plc and its subsidiaries. All rights reserved.

In This Topic
TitleResults for “How to create a CRG?”Also Available in