Enable an authentication protocol
- Last UpdatedMar 20, 2025
- 1 minute read
- PI System
- PI DataLink 2023 SP1
- Visualization
Note: When using PI Server 2023 and later, this section is only applicable if you have selected Windows authentication instead of OIDC authentication.
To connect to Data Archive with a defined PI mapping or PI trust, use PI System Explorer to enable the corresponding protocol on your computer. You must configure each computer where you connect to Data Archive with a PI mapping or PI trust.
-
Select Start > PI System > PI System Explorer to open PI System Explorer.
-
Select Tools > Options to open the Options dialog.
-
Select the Server Options tab on the Options dialog.
-
In the PI Data Archive Connection Setting section, use the arrow keys and checkboxes to sort and enable the protocols listed in Protocols.
-
To use PI mappings, Windows Security must be checked. This should be the first protocol in the Protocol order list.
-
To use PI trusts, PI Trust must be checked.
-
-
Select OK.