Analytics and Notifications for PI System Explorer (PI Server 2018)

PctGood

  • Last UpdatedJan 11, 2023
  • 1 minute read

Find the time-weighted or event-weighted percentage, over a specified time range, for which the attribute had good values.

Syntax

PctGood(attname, starttime, endtime [, calculationBasis])

Arguments

  • attname

    attribute with time series data (such as PI point data reference) enclosed in single quotes

  • starttime

    time expression representing the beginning of a time range enclosed in single quotes; can be a relative time (such as'-3h') in reference to an absolute endtime

  • endtime

    time expression representing the end of a time range enclosed in single quotes; can be a relative time (such as '+1h') in reference to an absolute starttime

  • calculationBasis

    Optional. A string indicating the type of calculation to be performed enclosed in double quotes. Choose between "TimeWeighted" or "EventWeighted". If omitted, the default is time-weighted

Returns

An integer or real number from 0 to 100: time-weighted or event-weighted minimum time percentage during a specified time range for which the attribute had good values

Example

  • PctGood('att1', 't', '+1h')

    [Return the time-weighted percentage between 12:00 and 1:00am today for which 'att1' had good values]

  • PctGood('att1', '-1h', '*')

    [Return the time-weighted percentage between now and hour ago today for which 'att1' had good values]

  • PctGood('att1', '-1h', '*', "EventWeighted")

    [Return the event-weighted percentage between now and hour ago today for which 'att1' had good values]