Steam_VsatT

  • Last UpdatedJan 11, 2023
  • 1 minute read

Calculate the saturated vapor specific volume as a function of temperature (T in °C). By default, input arguments and returned values are in SI units. You can change the units of measure, for example, by using the Convert function.

Syntax

Steam_VsatT(T)

Arguments

  • T

    Temperature of the steam. T can range from 0.0 to 373.946 °C.

Returns

Computed saturated vapor specific volume in cm3/g.

Example

  • Steam_VsatT(250)

    [Returns 50.087 cm3/g]