Configure the server list
- Last UpdatedFeb 27, 2023
- 2 minute read
- PI System
- PI Connector for CygNet 1.7.0
- Connectors
Add and configure Data Archive and PI AF for communication with the connector.
You can add and remove servers without stopping the connector data collection.
Note: The connection status of a server stays Disconnected until the connector begins collecting data.
-
On the PI Connector Administration page, click the Server List link.
The Server List pane displays the Data Archive and PI AF servers for the connector.
-
Add and configure one or more Data Archive servers to the PI Data servers list, and then click Add.
Note: For a Data Archive collective, add each member of the collective to the PI Data servers list, not the collective itself.
-
PI Data servers
A descriptive name or alias for the Data Archive server.
-
Hostname or IP address
The host name or IP address of the Data Archive server.
-
-
Add and configure one or more PI AF servers to the PI Asset servers list, and then click Add.
-
PI Asset servers
A descriptive name or alias for the PI AF server.
-
Hostname or IP address
The host name or IP address of the PI AF server.
-
-
Enter additional information for the PI AF server, and then click Keep these settings.
-
PI Asset Database
The name of the PI AF database.
-
Root PI Asset Path
The path to the PI AF element named "connector name Connector", under which the connector creates an asset hierarchy. The path can be empty. A non-empty path must conform to the PI AF syntax for element paths with the restriction that the path cannot begin or end with a backslash path separator character.
-
PI Data server
The host name or IP address for the associated Data Archive.
-