Transfer configuration of the General tab
- Last UpdatedSep 20, 2024
- 2 minute read
You can transfer the configuration of the General tab options of the InTouch Alarm Viewer control to the Alarm Client Control.

|
InTouch option |
Alarm Control option |
|---|---|
|
Perform Query on Startup |
In the Alarm Client Control, this option is called Query on Startup. You can configure this option on the Run-Time Behavior page. |
|
Show Context Sensitive Menu |
In the Alarm Client Control, this option is called Show Context Menu. You can configure this option on the Run-Time Behavior page. |
|
Configure Context Menus |
In the Alarm Client Control, you can configure the availability of individual shortcut menu options at run-time directly on the Run-Time Behavior page. |
|
Use Default Ack Comment |
In the Alarm Client Control, you can configure the availability of the Query Filters shortcut menu option on the Run-Time Behavior page. |
|
Retain Suppression |
In the Alarm Client Control, this option is called Retain Hidden. You can configure it on the Run-Time Behavior page. |
|
Show Status Bar |
In the Alarm Client Control, you can configure the Show Grid option on the Run-Time Behavior page. |
|
Show Heading |
In the Alarm Client Control, you can configure the Show Status Bar option on the Run-Time Behavior page. |
|
Row Selection |
In the Alarm Client Control, this option is called Row Selection. You can configure it on the Run-Time Behavior page. |
|
Use Extended Selection |
In the Alarm Client Control, this option is called Row Selection. You can configure it on the Run-Time Behavior page. |
|
Show Grid |
In the Alarm Client Control, you can configure the Show Grid option on the Run-Time Behavior page. |
|
Retrieve Buttons |
In the Alarm Client Control, the retrieve buttons are not available. The underlying grid technology handles the alarm retrieval from the alarm database. |
|
Silent Mode |
In the Alarm Client Control, this option is called Hide Errors and Warnings. You can configure it on the Run-Time Behavior page. |
|
Flash Unack Alarms |
In the Alarm Client Control, you can configure the Flash Unack Alarms option on the Colors page. |
|
Show Message |
In the Alarm Client Control, this option is called Show Custom ‘No Records’ Message. You can configure it on the Run-Time Behavior page. |
|
Font |
You can configure this option from the Industrial Graphic Editor page. Select the Alarm Client Control on the canvas and select an appropriate font type, size, and style on the menu bars. |
|
Column Details |
In Alarm Client Control, you can configure the column details directly on the Column Details page. |