AVEVA global performance improvement parameters

  • Last UpdatedNov 15, 2024
  • 1 minute read

AVEVA Global Performance Improvement Parameters

FILE

PARAMETER

VALUE

COMMENT

Admindwcf.config
globalwcfclient.config

<netTcpBinding> section

Maxbufferpoolsize

1048576

Increasing these from 65536 to 1048575 in both config files for all AVEVA software (on servers and client machines) resolves issues with a message size quotas being exceeded.

Maxbuffersize

1048576

Maxreceivemessagesize

1048576

Multids<xxx>.bat

AVEVA_ADMIND_BUFFER

100

Increasing to 100 improved allocate all performance in our env and based on MVW analysis, I think we stick with 100.