February

  • Last UpdatedJun 23, 2026
  • 2 minute read

The following updates were made as part of the Point Cloud Manager on CONNECT v25.6.0 release.

New features and enhancements

  • Admin panel update: For customers who are on the 2025 Point Cloud Manager service, there is a new landing page for the Point Cloud Manager service. When you select to open a project in the admin panel, this directly opens the admin page and locates the project. This update means a URL can be used to direct to specific projects.

  • Panoramic and BubbleView support: You can now import panoramic images along with terrestrial source scans. This should follow the "scanname _pano.jpg" naming convention. When imported, the panoramic images will be included in the scan resources and used in generation of the dataset.

    When generated, you will be able to switch between panoramic and BubbleView images. This can be used for low resolution scans.

    Option to switch between a BubbleView and its associated panoramic image

  • AIM integration settings: When you enable an integration service, you can now manage it within the admin page for Point Cloud Manager. This gives administrators access to turn on and off integrations and update when necessary.

  • Removal of HyperBubble resources: When you generate a dataset through the CONNECT admin page, HyperBubble resources are no longer generated.

  • Reorder dataset list: You can now reorganize the datasets in any order required from the admin panel. The order of this list will be respected when accessed through Viewer and the Desktop application.

Resolved issues

  • Case - N/A - (Defect - 4411109) - Improved super high E57 conversion: Fixed an issue where high resolution scans would fail to convert when using the Point Cloud Manager on CONNECT generation process.

  • Case - N/A - (Defect - 4118326) - Classification process failing: Fixed an issue where classifying a project through the admin panel would not complete in certain instances. This has been resolved for unstructured data.

  • Case - N/A - (Defect - 4444963) - BubbleView scanner markers: Fixed an issue with the visibility of scanner markers. Scan markers will now scale with the distance the viewer is from the scan markers.

  • Case - N/A - (Defect - 4506406) - User usage report not populating: Fixed an issue where the CONNECT user activities log within Point Cloud Manager Viewer did not work as expected in current versions.

Known issues

  • Case - N/A - (Defect - 4454520) - Large unstructured E57 files failing: There have been reports of Point Cloud Manager having issues with large E57 files of unstructured data.