Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI Interface for OPC Alarms and Events

OPC Alarms and Events 1​.7​.2

  • Last UpdatedOct 20, 2026
  • 3 minute read

The OPC Alarm and Events specification defines a means for transmitting alarm and event information between OPC servers and clients.

PI Interface for OPC Alarms and Events 1.7.2, released July 2023, is a maintenance release that focuses on improving the stability and usability of the interface.

For more information on product features and functions, including system requirements and installation/uninstallation instructions, refer to PI Interface for OPC Alarms and Events guide.

The latest information about the OPC Alarms and Events 1.7.2 release is available online on the AVEVA Documentation Portal.

New features and enhancements

There are no new features or enhancements in this release.

Resolved issues

This section lists items resolved in this release:

Work Item

Description

49840

PI Interface for OPC Alarms and Events parameter /RF now activates the setting.

52713

IO Rate Health tag to update as expected when the heartbeat tag updates.

52734

The interface no longer allows the user to add more than 32 event category attributes per event category.

52744

Code Page can now be set by the customer with the /codepage parameter.

52790

The command line parameters are now properly handled and not ignored.

69051

The PI Interface for OPC Alarms and Events AEConfig now adheres to Microsoft's COM Security policy of Packet Integrity.

70399

The Interface is able to read alarms and events data from a DeltaV AE server when using a wildcard coupled with the area in the InstrumentTag PI Tag Attribute.

Additionally, the following items were resolved for OPC Alarms and Events - ICU Control:

Work Item

Description

52730

Negative event category no longer triggers an Error Dialog.

52734

The interface no longer allows the user to add more than 32 event category attributes in the ICU Control.

Known Issues

There are no known issues for this release.

Security information and guidance

We are committed to releasing secure products. This section is intended to provide relevant security-related information to guide your installation or upgrade decision.

We proactively disclose aggregate information about the number and severity of security vulnerabilities addressed in each release. The tables below provide an overview of security issues addressed and their relative severity based on standard scoring.

Overview of new vulnerabilities - Fixed or Mitigated

This section is intended to provide relevant security-related information to guide your installation or upgrade decision. AVEVA is proactively disclosing aggregate information about the number and severity of PI Interface for AVEVA Batch Management security vulnerabilities that are fixed in this release.

For this release of PI Interface for AVEVA Batch Management, the following vulnerabilities have been fixed or mitigated.

Security vulnerabilities fixed in PI Interface for OPC Alarms and Events 1.7.2 release

Severity Category

CVSS Base Score Range

Number of Fixed Vulnerabilities

Critical

9 - 10

0

High

7.0 - 8.9

0

Medium

4.0 - 6.9

0

Low

0 - 3.9

0

Distribution Kit Files

Product

Software Version

PI Interface for OPC Alarms and Events

1.7.2.49

PI Interface for OPC Alarms and Events - ICU Control

1.7.2.49

OSIsoft MS VB Runtime Redistributables

1.0.1

Microsoft Visual C++ 2019 Redistributable (x86 and x64)

14.21.27702

PI SDK 2018 SP1 Patch 3 (x86 and x64)

1.4.7.620

PI GenericNames DLL

1.3.5.25

PI Spt DLL

1.2.4.0

PI Network Subsystem Support (PINS)*

3.4.435.538

PI Interface Configuration Utility

1.5.1.10

PI Buffer Subsystem 2018 SP2 Patch 2

4.9.0.37

* - The PI Network Subsystem Support (PINS) component is not displayed on the installation welcome screen if the PI Data Archive is installed already.