Maximum Stop Time
- Last UpdatedOct 04, 2024
- 1 minute read
- PI System
- PI Server 2023
- PI Server
Use this option to set the time the interface waits after a second interrupt message (Ctrl+C) before the interface forces an exit. This parameter is used when the interface is run in the interactive mode. The default value is 120 seconds.
Maximum Events in Event Pipe, Maximum Stop Time and Retry Timeout can be set either through the Batch Generator tool, which stores configuration data in the Module Database, or as a command line parameter. During startup, the interface uses whichever value is the non-default value. A message in the pipc.log file indicates which of the two values is being used. If both values are non-default, the value stored in Module Database takes precedence. While the interface is running, any changes made to the parameters through the Batch Generator tool are picked up by the interface without the need to restart the interface.