Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI System Management Tools

StmEng_TPH

  • Last UpdatedSep 17, 2025
  • 1 minute read

Calculates the steam temperature as a function of pressure and enthalpy—all variables expressed in English units. Use for both superheated and wet steam.

Format

StmEng_TPH(P, H)

Arguments

  • P

    Pressure of the steam in psia. The valid range is 0.08865 to 14503.77 psia..

  • H

    Specific enthalpy of the steam in BTU/lbm. The valid range is -0.017879547 to 1744.60206 BTU/lbm.

Returns

Computed steam temperature in °F or Error digital state.

Sample Values

Pressure

Enthalpy

Temperature

State

300.

1526.2

999.1

Superheated

800.

1511.4

998.7

Superheated

1400.

1493.2

998.8

Superheated

5000.

1364.6

999.0

Superheated

300.

1122.

417.37

90 % vapor