Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI System Management Tools

StmEng_HPT

  • Last UpdatedSep 17, 2025
  • 1 minute read

Calculates the vapor specific enthalpy as a function of pressure and temperature—all variables expressed in English units. Only use for superheated or dry saturated steam. An error of -1 (or input out of range digital state) returns for input temperature lower than the saturation temperature for the input pressure. However, the function computes for the full range of temperature for input pressure greater than the critical pressure.

Format

StmEng_HPT(P, T)

Arguments

  • P

    Pressure of the steam in psia. The valid range is 0.08865 to 14503.77 psia for temperatures up to 1472 °F and 0.08865 to 7251.8869 psia for temperatures up to 3632 °F.

  • T

    Steam temperature in °F. The valid range is 32 to 1600 °F.

Returns

Computed vapor specifically enthalpy in BTU/lbm or Error digital state.

Sample Values

Pressure

Temperature

Enthalpy

300.

1000.

1526.7

800.

1000.

1512.1

1400.

1000.

1494.0

5000.

1000.

1365.6

TitleResults for “How to create a CRG?”Also Available in