Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

PI System Management Tools

StmSI_TPH

  • Last UpdatedSep 17, 2025
  • 1 minute read

Calculates the steam temperature as a function of pressure and enthalpy—all variables expressed in SI units. Use for both superheated or wet steam.

Format

StmSI_TPH(P, H)

Arguments

  • P

    Pressure of the steam in KPa. The valid range is 0.611213 to 100000 KPa..

  • H

    Specific enthalpy of the steam in J/g. The valid range is 0.04158 to 4160.641 J/g.g.

Returns

Computed steam temperature in °C or Error digital state.

Sample Values

Pressure

Enthalpy

Temperature

State

2500.

3685.1

599.3

Superheated

5000.

3664.5

599.

Superheated

10000.

3622.7

598.9

Superheated

40000.

3346.4

598.9

Superheated

2500.

2617.0

223.96

90 % vapor

Note: Even if the input enthalpy is less than that of the saturated liquid, the function still returns the saturated temperature as the answer without setting an error state.