Attribute Category: Cabling
- Last UpdatedOct 24, 2024
- 3 minute read
|
Attribute Name |
Data Type |
Qualifier |
Description |
|
ACLIST |
element(500) |
Arriving cables to attached point |
|
|
ATCONN |
element(500) |
List of elements connected to attachment |
|
|
AYDIR |
dir |
Arrive Y axis direction |
|
|
BRLIST |
real(500) |
Bend radii of a cable |
|
|
CABBOX |
real(6) |
Calculated box volume in world coordinates |
|
|
CABGAP |
real |
cable gap on cabletray as multiple of OUTD |
|
|
CABINT |
string(120) |
cable interference class |
|
|
CABLAY(OUT) |
real |
Defines laying method for cables inside the branch. Attribute on %CWAY has no effect on functionality – it's used only to cascading down to CWBRAN during creation of new CWBRAN. |
|
|
CBACXR |
real |
integer |
Accumulated cables xarea at route node |
|
CBCOG |
pos |
Cable center of gravity |
|
|
CBCULE |
real |
Cut Length of cable |
|
|
CBFRLE |
real(20) |
Free Length of cable |
|
|
CBGELE |
real |
Geometric Length of cable |
|
|
CBNUCW |
element(500) |
Cables at a point on a cableway |
|
|
CBPREF |
element(500) |
References to POINTR forming route of a cable |
|
|
CBRNLS |
element(500) |
List of route nodes that cable passes |
|
|
CBRRLS |
element(500) |
List of route nodes and rattas that cable passes |
|
|
CBRWGL |
real |
Raw Geometric Length of cable |
|
|
CBSTT |
string(10) |
Cable status text |
|
|
CBTOLE |
real |
Total Length of Cable |
|
|
CBWEIG |
real |
Cable weight |
|
|
CENRAD |
Returns the center radius of CWBRAN volume at this particular point |
||
|
CENRADIUS |
real |
Centerline Radius |
|
|
CFCHE |
logical |
Fill level check |
|
|
CFILL |
real |
Fill level at route node |
|
|
CLIST |
element(500) |
integer |
All cables attached to route node |
|
CMAXF |
real |
Calculate maximum fill level on cway |
|
|
CMINF |
real |
Calculate minimum fill level on cway |
|
|
CONATS |
element(500) |
List of attachment connected to attachment |
|
|
CONBRA |
element(500) |
List of branches connected to branch |
|
|
CONNE |
logical |
Segment end connection flag |
|
|
CONNS |
logical |
Segment start connection flag |
|
|
CONSIS |
logical |
Position consistency |
|
|
CONTRA |
element(500) |
List of trays connected to branch |
|
|
CWJBLS |
element(500) |
Cableway branches and junction boxes list |
|
|
CWJUSL |
word |
Cable Way Justification Line |
|
|
CWLIST |
element(500) |
All cableways attached to route node |
|
|
CWPPJB |
element(500) |
Cableway branches and pull pits and junction boxes list |
|
|
CWPPLS |
element(500) |
Cableway branches and pull pits list |
|
|
DEPREF |
element(500) |
List of elements connected to branch tail |
|
|
DFBRAD(IUS) |
real |
Return value of radius at POINTR used to select correct specification component: Always inside radius at bends Inside or outside radius at risers *(depending whether riser is Inside/Outside) |
|
|
ELCXRF |
element(500) |
Return reference from CABLE element to ELCONN element |
|
|
ENBINF |
pos |
integer |
End bend information |
|
FCENTRE |
pos |
Center of fillet arc |
|
|
FEND |
pos |
Fillet arc position |
|
|
FILREF |
element(500) |
Sorted references to attachment points with ascending order of fill level greater then 0 |
|
|
FLEVEL |
real |
integer |
Fill level at route node |
|
FMID |
pos |
Middle point of fillet arc |
|
|
FSTART |
pos |
Fillet start position |
|
|
HDCONN |
element(500) |
List of elements connected to branch head |
|
|
HDREF |
element(500) |
List of attachment connected to attachment |
|
|
INSLEN |
real(200) |
Installation length |
|
|
INSMETHOD |
string(240) |
Getting installation method lengths. The output is a textual array describing length of installation method along the cable. Size of the array depends on how many different installation methods are applied along the cable route. |
|
|
INSRAD |
Returns the smallest radius of CWBRAN at this particular point |
||
|
INSRADIUS |
real |
Inside Radius |
|
|
INSTLV(EL) |
string(240) |
Getting installation level and dressing. The output is a textual array of 5 elements as follows: Free Route, <length> length of the part of the cable that is routed outside branch Underground Dressed, <length> … inside *underground dressed branch Underground Not Dressed, <length> ...inside underground undressed branch Above Ground Dressed, <length> ...inside above ground dressed branch Above Ground Not Dressed ...inside above ground dressed branch *underground – is determined by attribute UNDERG queried on the branch |
|
|
INVRAD(IUS) |
logical |
Returns true if cable uses a radius smaller than minimum radius for it's specification (see property MINBEN) |
|
|
JBLIST |
element(500) |
Junction boxes list |
|
|
LALCAB |
element(500) |
List arriving leaving cables on attached point |
|
|
LAYMOT |
string(100) |
integer |
Layout mode text |
|
LYDIR |
dir |
Leave Y axis direction on point |
|
|
MINFIL |
real |
Min Fill level on Cableway and Cabletray components |
|
|
NPLIST |
element(500) |
All NATPs attached to route node |
|
|
NUMCOR |
integer |
Number of cores in a cable |
|
|
OUTRAD |
Returns the biggest radius of CWBRAN at this particular point |
||
|
OUTRADIUS |
real |
Outside Radius |
|
|
OVCWIDTH |
real |
Overall cables width |
|
|
PRFELE |
element |
Cableway profile element |
|
|
PRFOBS |
integer |
Cableway profile obstructions |
|
|
PULLLS |
element(500) |
Pull pit list |
|
|
RADI |
real |
Obtains the radius of a cable at this particular point |
|
|
RCONAT |
element(500) |
element |
List of valid connected route attachments |
|
RILIST |
element(500) |
Route information list |
|
|
RMINIMUM |
real |
Scans all the routing points the cable is routed through and returns the minimal radius of the cable |
|
|
RNODEL |
element(500) |
word |
Rnode list |
|
ROUHEIGHT |
real |
Routing Height |
|
|
ROUWIDTH |
real |
Routing Width |
|
|
STBINF |
pos |
integer |
Start bend information |
|
STRJUS |
word |
Cable Way Justification Line |
|
|
TLCONN |
element(500) |
List of elements connected to branch tail |
|
|
TLREF |
element(500) |
List of attachment connected to attachment |
|
|
TXAREA |
real |
Total Cableway X-area |
|
|
VRADI |
real |
Cableway radius |