PI Integrator for Business Analytics

Manage access to multiple views

  • Last UpdatedMay 21, 2024
  • 2 minute read

You can select multiple views at one time and add View Access identities to them.

Note: You cannot remove identities from multiple views. You can only remove identities from one view at a time.

Identities that are added to views are given Owner permission by default.

The exception to this is if an identity is already assigned to a view. If the view is one amongst other views that are selected and the same identity is assigned to it, it retains whatever permissions were previously set. For example, the Engineers identity is assigned to View ABC and is given Reader permission to the view. Then View ABC is selected along with other views and the Engineers identity is assigned to all the views. In this case, the Engineers identity for View ABC retains its existing permissions setting, that is Reader. All other views are assigned the default Owner permission for the Engineers identity.

If a node goes down, the Cluster Manager reassigns any jobs that were assigned to it to the remaining worker nodes. The offline worker node is automatically restarted by the PI Integrator Framework service. Once restarted, existing jobs are not rebalanced to include the restarted worker node. However, new jobs are balanced across all working nodes. If this results in an unbalanced distribution of jobs, you can manually rebalance the jobs.

  1. Click the menu icon , and click Administration.

  2. Click the Views tab.

  3. Click in the left column of the views you want to select.

    Manage access to multiple views

  4. Click Add Identities to Selected Views under the View Access label.

    Note: If impersonation security setting is on, Data Access identities will also be shown.

  5. In the Add Identity window, select the identities you want to add and click Ok.

    Note: If the application impersonation security setting is turned on, Data Access will also be shown with a note "Multiple Views Selected" instead of the identities.