Unattended Silent Installation
- Last UpdatedOct 01, 2026
- 3 minute read
The installation of Plant SCADA can be executed via a command line with the required components specified via a configurable response file.
A response file specifies the set of components that will be installed during a silent installation. It represents the forms normally seen when interacting with the user interface of the Plant SCADA installer. The available options for each form are configured via a set of properties.
Four preconfigured response files are available for use:
-
All.txt – installs all components
-
DevelopmentWorkstation.txt – installs components for a development workstation
-
RuntimeClient.txt – installs components for a runtime client
-
Server.txt – installs components for a runtime server.
These can be used to install a typical set of components, or they can be used as reference for your own customized response file (see Customize a Response File).
The four files are available from the following directory within the Plant SCADA installation media:
InstallFiles\ResponseFiles
The following example shows the content of the Server.txt response file.
<responsefile>
<install>
ComputerRoleSelectionForm.SelectedComputerRoleName=Server
ServerRoleSelectionForm.ServerRolesList=RuntimeServer,DeploymentServer,
OPCUAServer,EnterpriseLicenseServer
FeaturesForm.SFeatureList=AVEVA Plant SCADA.Configuration,AVEVA Plant SCADA.Runtime,
AVEVA Plant SCADA.InTouchWebClient,AVEVA Plant SCADA.OpcUaServer,
AVEVA Plant SCADA.DeploymentServer
SecurityGroupForm.AddUserToGroups=true
FirewallForm.ModifyFireWall=true
CustomDestinationSelectionForm.InstallDirPath=
C:\Program Files (x86)\AVEVA Plant SCADA
CustomDestinationSelectionForm.ProgramDataPath=
C:\Program Data\AVEVA Plant SCADA 2026
LanguageValidationForm.LanguageCode=en-US
</install>
</responsefile>
You can also specify Configurator settings within a response file. See Add Configurator Settings to a Response File.
Localized installation
You can install a localized version of Plant SCADA when running a silent installation. To do this, modify the following entry in a response file:
LanguageValidationForm.LanguageCode=en-US
By default, English (US) is installed as specified by the language code "en-US".
Use the following codes to change this to one of the languages supported by Plant SCADA.
-
French = fr-FR
-
German = de-DE
-
Italian = it-IT
-
Japanese = ja-JP
-
Korean = ko-KR
-
Portuguese = pt-BR
-
Russian = ru-RU
-
Simplified Chinese = zh-CHS
-
Spanish = es-ES
The language you specify needs to match the parent language of the operating system. Use the language codes above, even if the operating system uses a different locale variant.
For example, to install a German version of Plant SCADA, make the following modification in the response file:
LanguageValidationForm.LanguageCode=de-DE
This setting is valid for both de-DE (Germany) and de-AT (Austria) operating system variants.
Note: A silent installation will not be successful if a language code is not specified, invalid, or not compatible with the installed operating system.
Silent Install/Uninstall Commands
Open a command prompt as an administrator, then run the following commands.
-
Command for installation:
Setup.exe /silent "<Response File Path>"
The specified response file needs to be text-based. A full absolute path needs to be provided. For example:
Setup.exe /silent "D:\PlantSCADA\MyResponseFiles\All.txt"
You can also use the "silentnoreboot" option to suppress a machine reboot after installation completes, for example:
Setup.exe /silentnoreboot "<Response File Path>"
-
Command for uninstallation:
Setup.exe /silentuninstall <ID of Plant SCADA>
For example:
Setup.exe /silentuninstall {XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX}
The ID for Plant SCADA can be retrieved from the Setup.xml file, located in the InstallFiles directory within the installation media.
Search for the ID value within the <mainproduct> tags.
Note: Do not manually uninstall any non-core components (such as AVEVA Enterprise Licensing, the Sentinel Driver, PCS, Operation Control Logger or AVEVA Help) prior to running a silent uninstall of Plant SCADA as the silent uninstall may not be successful.
When you run a silent uninstallation, you need to follow the procedure below when also uninstalling any non-core components.
-
Uninstall AVEVA Plant SCADA's core components (using the silent uninstall command).
-
Uninstall AVEVA Enterprise Licensing components:
-
AVEVA Enterprise License Server
-
AVEVA Enterprise License Manager
-
AVEVA Enterprise Licensing Platform.
-
-
Uninstall Sentinel System Driver Installer.
-
Uninstall AVEVA Platform Common Services.
-
Uninstall Operations Control Logger.
-
Uninstall AVEVA Help.
Note: You can also use a command to silently install a Plant SCADA update. See Silently Install a Plant SCADA Update.