ModbusBridge Object
- Last UpdatedFeb 16, 2016
- 2 minute read
To add ModbusBridge objects to your MBTCP hierarchy
-
Right-click on the TCPIP_PORT branch.
-
Select Add ModbusBridge Object from the shortcut menu.
-
Default name is New_ModbusBridge_000.
Note: You can add up to 247 objects of each type to the hierarchy. However, the bridge itself limits the number of PLCs that can be connected to the serial line.
-
-
Rename as appropriate.
-
The New_ModbusBridge_000 Parameters configuration view is displayed.

This configuration view has three configurable elements.
-
Bridge type: From the drop-down menu, select the type of communications bridge to use for the connection to the TCP/IP Port.
Default bridge type
Alternative bridge type
Modbus Bridge
-
This attribute is editable
-
Maximum number = 4
-
Minimum number = 1
-
Default value = 2
NR&D Pen-T Bridge
-
This attribute is not editable
-
Value of this attribute = 1
-
-
Network address: Enter the host name or IP address of the bridge.
-
The number of characters should not exceed 255.
-
The field cannot be blank (number of characters cannot be zero).
-
The default value is 1.0.0.0.
-
-
Maximum outstanding messages: Enter the maximum number of queued messages allowed in the Modbus Bridge.
Note: The Bridge Type used governs the value configured.
From the ModbusBridge branch of the OI Server hierarchy, the following objects can be created:
-
Compact984 Object
-
ModiconMicro Object
-
TSXMomentumRS Object
-
ModbusPLCRS Object
For further instructions on adding these objects, see Adding the Compact984, ModiconMicro, TSXMomentumRS, or ModbusPLCRS Objects to the MBTCP Hierarchy.
-
-