Optional settings
- Last UpdatedJun 26, 2026
- 1 minute read
The following parameters are available to configure for redundant servers:
|
Parameter |
Description |
|---|---|
|
Port |
Identifies the network port used to connect to the redundant MQTT broker. Required only if Protocol is TCP. |
|
Protocol |
Defines the connection protocol used for the redundant MQTT broker. Select WS or TCP from the drop-down. |
|
Tls |
Enables or disables secure communication with the redundant MQTT server. Enable Tls when the MQTT broker requires an encrypted connection. Select None, TLS, TLS11, TLS12, TLS13 from the drop-down. |
|
User Name |
User name or client Id for accessing the server. |
|
Password |
Password or token for accessing the server. |
|
Client Certificate Thumbprint |
The thumbprint of the certificate when the broker requires a client certificate. |
|
Client Certificate Password |
(Protected) - The password to access the certificate when the broker requires a client certificate. |
|
Validate Server Certificate |
Determines if the server certificate gets validated. Note: A warning is printed in case the server certificate validation is disabled. |
|
Server ID |
Unique GUID for the Server. |