Security
- Last UpdatedJun 30, 2026
- 1 minute read
See flow runtime installation for information on when to set each setting.
|
Variable |
Value |
Description |
|---|---|---|
|
SecurityConfiguration__Registration__Key |
Unique key |
The global registration key created in flow manager |
|
SecurityConfiguration__Registration__Name |
Unique Node name |
A unique name to use when registering the node. Not needed if auto-generated names are configured in Flow manager |
|
SecurityConfiguration__Registration__Name |
|
|
|
SecurityConfiguration__Credentials__NodeId |
Unique ID from flow manager |
ID to use when registering a single Flow manager (set by the installer on Windows) |
|
SecurityConfiguration__Credentials__AccessKey |
Key from flow manager |
Key to use when registering a single flow runtime (set by the installer on Windows) |
|
EdgeNodeConfiguration__RestApi__AllowKillHostFromApi |
false or (true) |
If true, the runtime host can be terminated through the flow runtime API or web UI. |
|
EdgeNodeConfiguration__RestApi__AllowKillProcessFromApi |
false or (true) |
If true, flows can be terminated through the flow runtime API or web UI. |
|
EdgeNodeConfiguration__RestApi__Allow |
false or (true) |
If true, remote sessions can be terminated through the flow runtime API or web UI. |