Galaxy migration errors after upgrading to SP2023R2SP1
- Last UpdatedAug 31, 2026
- 1 minute read
Issue:
When upgrading a machine with "AVEVA System Platform 2023 R2 (SP2023R2) with AVEVA Work Tasks 2023 SP1" to "AVEVA System Platform 2023 R2 SP1 (SP2023R2SP1) with AVEVA Work Tasks 2023 R2", users may encounter errors and warnings during galaxy migration.
Cause:
The issue arises due to missing or misplaced files required for successful galaxy migration after the upgrade.
Workaround:
Apply the following workaround before migrating galaxies to resolve the issue.
-
After completing the upgrade to SP2023R2SP1 on a machine with AVEVA Work Tasks 2023 R2, but before migrating any galaxies, perform these steps:
-
Navigate to the folder:
C:\Program Files (x86)\ArchestrA\Framework\Bin\AuthenticationProvider
-
Copy the files:
-
Microsoft.Extensions.Logging.Abstractions.dll
-
PCS.Client.DataStore.dll
-
-
-
Paste the copied files into the following folder:
C:\Program Files (x86)\ArchestrA\Framework\Bin
-
Restart the machine.
CONNECT / Deployment / Licensing
Issue:
If a Galaxy includes AVEVA Workflow Gateway objects and SP2023 R2 SP1 (P03 or P04) is applied on the node, you may see the following issues:
-
License acquisition failure
-
Deploy failure
-
System Platform IDE not opening with Aveva CONNECT SSO
Workaround:
If you experience any of these issues, do the following:
-
On the affected node, copy the following four files from C:\Program Files (x86)\ArchestrA\Framework\Bin\AuthenticationProvider:
-
Microsoft.Web.WebView2.Core.dll
-
Microsoft.Web.WebView2.WinForms.dll
-
Microsoft.Extensions.Logging.Abstractions.dll
-
PCS.Client.DataStore.dll
-
-
Paste the files to C:\Program Files (x86)\ArchestrA\Framework\Bin.
-
Restart the node.
Note: These instructions assume that the default installation path was used. If a non-default path was used, copy the files from the applicable path.