Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Historian

TIMESHIFT examples

  • Last UpdatedFeb 07, 2025
  • 1 minute read

Example

The following expression shifts the time stamp of each flow rate value forward by one hour.

TIMESHIFT( Pump101.Flow, Hour )

Example 2

The following expression shifts the time stamp of the current time's minute value back by two minutes.

TIMESHIFT( SysTimeMin, -2 minute )

Represented as a query:

SELECT DateTime, Value, OPCQuality

FROM History

WHERE wwExpression = 'TIMESHIFT( SysTimeMin, -2 minute )'

Results:

DateTime

Value

OPCQuality

2022-03-31 15:57:00.0000000

59

192

2022-03-31 15:58:00.0000000

0

192

2022-03-31 15:59:00.0000000

1

192

2022-03-31 16:00:00.0000000

2

192

...

...

...

In This Topic
Related Links
TitleResults for “How to create a CRG?”Also Available in