EstimateParameters Node
- Last UpdatedJul 12, 2024
- 3 minute read
The EstimateParameters node is used for path time calculations and contains the child nodes:
The nesting on a bar is controlled by the information given in the following nodes:
|
The TransportTimePerMeter contains one value given in seconds. |
|
The AddTimePerMarking contains one value given in seconds. |
|
The AddTimePerGSD contains one value given in seconds. |
|
The AddTimePerLabel contains one value given in seconds. |
|
The AddTimePerCutHole contains one value given in seconds. |
|
The AddTimePerDrillHole contains one value given in seconds. |
|
The AddTimePerSlottHole contains one value given in seconds. |
|
The AddTimePerSinkHole contains one value given in seconds. |
|
The AddTimePerTreading contains one value given in seconds. |
|
The NoofCuts contains three parameters, x, y and v, which defines the number of cuts needed to cut any of the basic edge preparation types. |
|
The BurnerSpeed contains one value given in seconds per meter. |
The nesting on a plate is controlled by the information given in the following nodes:
|
Preparation is a node with the following child nodes: MainPrep_1 contains one value given in minutes. It is the main preparation time and it will be used once for the main burner. MainPrep_2 contains one value given in minutes. It is main preparation time and it will be used once for the additional burners. AddPrep contains one value given in minutes. It is the additional preparation time and it will be used once for each burner. PrepConst contains three values. First is an additional constant due to some surface treatment that must be given to one or both sides. It is given in min/ nested plate. Second and third value are string codes for the surface on this and other side of the plate. |
|
|
Rationalization |
is used to present a summary of the path times using different rationalization factors and it contains three values; a pretext string to be written before the summary, a factor to be applied to the path time and a post text to be written after the summary. |
|
The MarkingTime contains one value given in minutes per meter. |
|
|
The MarkingStart contains one value given in minutes. |
|
|
The GSDTime contains one value given in minutes per meter. |
|
|
The GSDStart contains one value given in minutes. |
|
|
The LabelTime contains one value given in minutes per character. |
|
|
The LabelStart contains one value given in minutes. |
|
|
The BlastingTime contains one value given in minutes per meter. |
|
|
The BlastingStart contains one value given in minutes. |
|
|
The IdleFast contains one value given in minutes per meter. |
|
|
The IdleSlow contains one value given in minutes per meter. |
|
|
The AddTimePerCutting contains one value, the starting time in minutes for a cutting. Normally this keyword is defined within a thickness interval. |
|
|
The BurnerSpeed contains one value, the burning time in minutes per meter. Normally this keyword is defined within a thickness interval. |
|
|
The BurnerSpeedVBevel contains one value, the burning time in minutes per meter for an edge with V bevel. Normally this keyword is defined within a thickness interval. |
|
|
The BurnerSpeedYBevel contains one value, the burning time in minutes per meter for an edge with V bevel. Normally this keyword is defined within a thickness interval. |
|
|
The BurnerSpeedXBevel contains one value, the burning time in minutes per meter for an edge with V bevel. Normally this keyword is defined within a thickness interval. |
|