This release contains the following significant enhancements and defect fixes:
Core Functionality
|
Reference |
Type |
Description |
|---|---|---|
|
1087074 |
Enhancement |
When processing files through the AutoCAD 2D Gateway, WIPEOUTFRAME variables for wipeout objects are now supported. |
|
1464187 960070871 |
Enhancement |
When processing files through the AutoCAD 2D Gateway, bitonal raster images are now supported. |
|
1981070 960165756 |
Defect |
When processing files through the AutoCAD 2D Gateway, improvements have been made to the accuracy of scraping tags. This avoids incorrect concatenation of text. For example, 1234567890-ABC versus ABC-1234567890. Any files that had this issue will need to be re-processed. |
|
2035115 960208296 |
Defect |
When processing files through the AutoCAD 2D Gateway, some DWG files had the error “Error processing DWG/DXF file. Attempted to read or write protected memory.”. Any files that had this issue will need to be re- processed. |
|
2138930 |
Defect |
When processing files through the AutoCAD 2D Gateway, high density DOT patterns will be replaced with a solid fill pattern. This greatly reduces processing time and SVG file size. |
|
2183065 960238020 |
Defect |
When processing files through the AutoCAD 2D Gateway, some DWG files had the error “Gateway extraction error: documents may contain broken objects.”. Any files that had this issue will need to be re- processed. |
|
2250575 960217548 |
Defect |
When processing files through the AutoCAD 2D Gateway, drawing content may have been misaligned. Any files that had this issue will need to be re- processed. |
|
2296389 960252549 |
Defect |
When processing files through the AutoCAD 2D Gateway, some instrument tags were not captured in the SVG file. Any files that had this issue will need to be re- processed. |
|
2299871 960254316 |
Defect |
After running a Query Form, if a Reset was performed, then any links to documents, shown in the set of results, were still visible and active. Any links to documents are now removed after the reset. |
|
2312424 960251305 |
Defect |
When processing files through the AutoCAD 2D Gateway, some files were incorrectly referring to missing XREF files in the SVG as they were not displayed in the source drawing. Any files that had this issue will need to be re- processed. |
|
2328846 960244129 |
Defect |
If a single XML file was imported, that tried to perform multiple re-parenting of classes in the same hierarchy, then the Import Server may have terminated. An example would have been, if the hierarchy was C1-C2-C3-C4 and a single XML file tried to make C2 the parent of C4 and C4 the parent of C3 (affectively switching C3 and C4 in the hierarchy). |
|
2336299 960265587 |
Defect |
When processing files through the AutoCAD 2D Gateway, some diagonal lines were incorrectly appearing on the SVG drawing. Any files that had this issue will need to be re- processed. |
|
2346504 960267141 |
Defect |
After running a Query Form that returned a single result, switching from Table View to Form View did not populate the list of attributes in the Form View. |
|
2391755 960246950 |
Defect |
LinkClass attributes imported from ISM containing dots or commas were not appearing as hyperlinks in the Dashboard. |
|
2391777 960246950 |
Defect |
LinkClass attributes imported from ISM containing @ symbols were appearing in the Dashboard as mailto links rather hyperlinks. |
|
2436972 |
Enhancement |
Support for CONNECT service integration. This allows for applications to provide data to the Data Pipeline or for applications to read data from AIM-A. Note: This functionality is restricted, please contact your AVEVA representative to discuss access to this functionality. For more information, please see https://docs.aveva.com/bundle/asset-information-management/page/1252243.html |
|
2503863 960252067 |
Defect |
Security improvements. |
|
2514762 |
Process |
Updated the release to the latest Microsoft patches. |
Document Connector
|
Reference |
Type |
Description |
|---|---|---|
|
2390553 |
Enhancement |
It is now possible to filter on the source of files and transactions. The source value can be customized for data coming from the Gateway Data Publisher and from Worktask (from August). For the Document Connector, it is pre-defined based on the DMS used. For more information, please see https://docs.aveva.com/bundle/asset-information-management/page/1047906.html |
|
2395508 |
Enhancement |
Support for SharePoint integration. For more information, please see https://docs.aveva.com/bundle/asset-information-management/page/1236924.html |
|
2415660 |
Defect |
If a Tenant ID was created with a hyphen, then any scheduled jobs were failing with the message "Invalid assetId parameter". |
|
2500719 |
Enhancement |
For integration with Aconex, a pagination capability has been provided. The page size needs to be configured and the value must be divisible by 25 up to a maximum of 500. For more information, please see https://docs.aveva.com/bundle/asset-information-management/page/1161672.html |
Data Pipeline
|
Reference |
Type |
Description |
|---|---|---|
|
2527805 |
Enhancement |
The Registers Gateway has been improved to allow the use of expressions in the Association Register. For example, this would allow a context to be added to a target object when creating associations, in particular when the data has multiple target objects. For example, DOC-001 has association “is a document for” PLANT-A|TAG-001;PLANT-B|TAG-002 This will allow the creation of associations by executing the expression during capture operation, for example:
Note: The expressions are applied when the input rows are being read, which does have the negative aspect of being non-reversible, so would need to be used with caution. It is strongly advised to test the expression before pushing it to production. |
Data Pipeline - Load Reporting
|
Reference |
Type |
Description |
|---|---|---|
|
2165495 |
Defect |
When viewing the transaction history of a file, the Load more results link was not returning the next page of results (a 2nd click was needed to return the results). |
|
2212759 |
Defect |
The pre-defined time filters (2 Hours, 6 Hours, etc) may not have shown the full set of results. |
|
2283413 |
Enhancement |
The user experience has been improved, including the user’s flow through the website, a restyling of the filtering mechanism and general improvements to styling and layout. For more information, please see https://docs.aveva.com/bundle/asset-information-management/page/1047888.html |
|
2360927 |
Enhancement |
When using the Load Reporting Portal to monitor loads via the Data Pipeline, improvements have been made to the error messages from the Registers Gateway, which provides more detailed responses. Also remediations specific to each error code have been added. |
|
2487670 |
Enhancement |
The following file state has been renamed: • Orchestration Completed -> Completed For more information, please see https://docs.aveva.com/bundle/asset-information-management/page/1047907.html The following transaction states have been renamed: • Orchestration Completed (Amber) -> Partially Completed • Orchestration Completed (Green) -> Completed For more information, please see https://docs.aveva.com/bundle/asset-information-management/page/1047908.html |
|
2489808 960295447 |
Defect |
If a file failed to be ingested into the Data Pipeline, the user was unable to view the failure logs if the file name contained any URL encoding characters. For example, Test%20File.csv. |